What are the BB93 reverberation time limits?

The BB93 reverberation time limits are the maximum mid-frequency reverberation times, Tmf, that table 6 of Building Bulletin 93 sets for each type of school room in England, with one column for new build and one for refurbishment. A new build primary classroom may not exceed 0.6 seconds; a refurbished one may not exceed 0.8 seconds.[1]

Key points

  • Table 6 of BB93 is the source of every figure on this page, read from the February 2015 edition of the document; the GOV.UK page for it was last updated on 19 December 2014.[1][2]
  • Values are for rooms that are finished and furnished for normal use but unoccupied.[1]
  • Refurbishment values are also the least demanding standard allowed as an alternative performance standard in a new building.[1]
  • Rooms intended specifically for pupils with special hearing or communication needs have a separate, tighter limit.[1]

How the limits are applied

Tmf is the arithmetic average of the reverberation times in the 500 Hz, 1 kHz and 2 kHz octave bands, or of the one-third octave bands from 400 Hz to 2.5 kHz.[1] For rooms intended specifically for pupils with special hearing or communication needs the average runs across the 125 Hz to 4 kHz octave bands instead.[1]

The numbers

Table 6 reproduced from BB93. Values are maximum Tmf in seconds. Where a range is shown, reverberation time should fall within it, ends included.[1]

Room typeNew build (s)Refurbishment (s)
Nursery room; primary classroom, class base, general teaching area, small group room, SEN calming room0.6 [1]0.8 [1]
Secondary classroom, general teaching area, seminar, tutorial or language room; study room; science laboratory; design and technology rooms; ICT room; art0.8 [1]1.0 [1]
Open plan teaching area0.5 [1]0.5 [1]
Open plan resource or breakout area1.2 [1]1.2 [1]
Primary music room; secondary music classroom1.0 [1]1.0 [1]
Music practice or group room, volume 30 m3 or less0.6 [1]0.8 [1]
Music practice or group room, volume over 30 m30.8 [1]1.0 [1]
Ensemble room, live room0.6 to 1.2 [1]0.6 to 1.2 [1]
Performance or recital room1.0 to 1.5 [1]1.0 to 1.5 [1]
Music control room0.5 [1]0.6 [1]
Lecture room, fewer than 50 people0.8 [1]1.0 [1]
Lecture room, more than 50 people1.0 [1]1.0 [1]
Teaching space intended specifically for students with special hearing or communication needs0.4 averaged over 125 Hz to 4 kHz, and no more than 0.6 in every octave band [1]0.4 [1]
Library1.0 [1]1.2 [1]
Drama studio1.0 [1]1.0 [1]
Assembly or multi-purpose hall0.8 to 1.2 [1]0.8 to 1.5 [1]
Gymnasium or activity studio1.5 [1]2.0 [1]
Dance studio1.2 [1]1.5 [1]
Meeting, interview or counselling room0.8 [1]0.8 [1]
Dining room1.0 [1]1.5 [1]
Office, medical room, staff room1.0 [1]1.2 [1]
Atrium, foyer, entrance hall or circulation space not used for teaching1.5 [1]2.0 [1]
Kitchen, coats and locker area, changing area, toilet1.5 [1]2.0 [1]

Sports halls and swimming pools depend on floor area (BB93 table 7), in new build.[1]

  • Floor area under 280 m2: 1.5 s.[1]
  • Floor area 280 to 530 m2: 2.0 minus (530 minus the floor area) divided by 500, in seconds.[1]
  • Floor area over 530 m2: 2.0 s.[1]
  • Refurbishment: 2.0 s.[1]

Corridors and stairwells have no table 6 figure: BB93 points to the absorption calculation in Approved Document E, section 7.[1]

In schools and SEN settings

BB93 says pupils with special educational needs are generally more sensitive to the acoustic environment, so the required reverberation times are shorter for their rooms.[1] The 0.4 s row applies to a teaching space intended specifically for students with special hearing or communication needs.[1] BB93 notes that alternative performance standards are commonly required for these rooms and should be agreed by an acoustician and the school client body.[1]

A SEN calming room sits in the primary classroom row, at 0.6 s for new build and 0.8 s for refurbishment, not in the 0.4 s row.[1] The design guide from the Institute of Acoustics and the Association of Noise Consultants gives more detail on rooms for pupils with special hearing requirements.[3]

Worked example

An illustrative primary classroom measures a Tmf of 0.75 s after refurbishment (an invented figure).[1] Against table 6 it passes the refurbishment limit of 0.8 s and fails the new build limit of 0.6 s.[1] Which one applies depends on whether the work is new build or refurbishment.

What people get wrong

  • Quoting 0.4 s for every classroom. That figure is for rooms intended specifically for pupils with special hearing or communication needs, not for ordinary classrooms.[1]
  • Using refurbishment values for new build. They are the floor for an alternative performance standard, which needs a documented case.[1]
  • Applying the limits to occupied rooms. The values are for rooms that are finished, furnished and unoccupied.[1]

How it is checked

For sports halls, swimming pools and similar normally unfurnished spaces, compliance may be shown by design to the Institute of Acoustics guide or by measuring Tmf following the Association of Noise Consultants testing guide.[1]

FAQ

What is the BB93 reverberation time for a primary classroom?

0.6 s for new build and 0.8 s for refurbishment.[1]

What is the limit for a secondary classroom?

0.8 s for new build and 1.0 s for refurbishment.[1]

What is the limit for an open plan teaching area?

0.5 s for both new build and refurbishment, with the speech transmission index also applying under the School Premises Regulations.[1]

WorkSpace Acoustics surveys and installs acoustic treatment for schools; contact the team to discuss a room.

Sources

  1. Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.
  2. Acoustic design of schools: performance standards: BB 93. GOV.UK (Department for Education), last updated 19 December 2014. Accessed November 2026.
  3. Acoustics of Schools: a design guide. Institute of Acoustics and Association of Noise Consultants, November 2015. Accessed November 2026.
Expert acoustic consultancy and installation for schools, businesses and restaurants across the UK. Specialists in SEN environments.
A specialist division of: Presentation Spaces Group

COMPANY

About
Why Acoustics
Contact Us
Privacy Policy
Glossary
Acoustics statistics

SECTORS

Schools
Businesses
Restaurants

SERVICES

Acoustic Surveys
Acoustic Design
Installation
© 2026 WorkSpace Acoustics Ltd. All rights reserved.
Product images courtesy of Presentation Spaces Group (used with permission)