What are the Control of Noise at Work Regulations 2005?

The Control of Noise at Work Regulations 2005 are the law in Great Britain that protects workers' hearing from noise. They set lower exposure action values of 80 dB(A) daily or weekly personal exposure, upper values of 85 dB(A) and an exposure limit value of 87 dB(A), with matching peak sound pressure values.[1][2]

Key points

  • The Regulations came into force for all industry sectors in Great Britain on 6 April 2006, except music and entertainment, where they came into force on 6 April 2008.[2]
  • They protect workers' hearing from noise at work. They do not apply to members of the public exposed to noise from non-work activities or to nuisance noise.[2]
  • Employers must assess risk at or above the lower exposure action value and must not expose employees above the exposure limit value.[1]
  • The Regulations replaced the 1989 Regulations and require action at levels 5 dB(A) lower than before.[2]

How it works

Regulation 4 sets the values, and regulations 5 to 9 set what an employer must do at each level.[1] The values are for noise exposure at work and are measured as A-weighted personal exposure, plus a C-weighted peak.[1]

At or above a lower exposure action value, the employer must make a suitable and sufficient risk assessment and record its significant findings, and must make hearing protectors available on request.[1] At or above an upper value, the employer must reduce exposure as low as reasonably practicable by organisational and technical measures, not counting hearing protectors, must provide protectors if exposure cannot otherwise be brought below that value, and must designate a Hearing Protection Zone.[1] Where risk to health is indicated, health surveillance including hearing tests must be provided.[1]

Lower and upper exposure action values

The numbers in regulation 4 are the heart of the Regulations.[1]

  • Lower exposure action values: 80 dB(A) daily or weekly personal noise exposure and a peak sound pressure of 135 dB(C).[1]
  • Upper exposure action values: 85 dB(A) and a peak sound pressure of 137 dB(C).[1]
  • Exposure limit values: 87 dB(A) and a peak sound pressure of 140 dB(C).[1]
  • The limit value takes account of hearing protectors that the employer provides; the action values do not.[1]

HSE summarises these as 85 dB(A) for hearing protection and protection zones, 80 dB(A) for risk assessment and information and training, and 87 dB(A) as the limit above which workers must not be exposed.[2] An employer may use weekly exposure in place of daily exposure where daily exposure varies markedly.[1]

In schools and SEN settings

The Regulations protect employees. Regulation 3(2) extends the duties, so far as reasonably practicable, to other people at work who may be affected, except health surveillance, and information and training for people not present at the workplace.[1] For a school, that means staff such as music or workshop teachers, caretakers and catering staff, where noise at work reaches the values. They do not set a limit for pupils in classrooms; BB93 does that, with an upper limit for indoor ambient noise of 35 dB LAeq,30min in a new build classroom.[3]

The two measures have different purposes: BB93's figure is about conditions for learning in an unoccupied room, while the Regulations' 80 dB(A) value is about hearing damage over a working day.[1][3] A room can meet one and say nothing about the other.

Worked example

An illustrative design and technology workshop has a teacher whose daily personal noise exposure is 82 dB(A), an invented figure.[1] That is above the lower exposure action value of 80 dB(A) and below the upper value of 85 dB(A).[1] The school as employer must carry out a risk assessment and make hearing protectors available on request, but the upper-value duties on protection zones do not yet apply.[1]

What people get wrong

  • Treating 85 dB(A) as the only threshold. HSE says the assessment, information and training level is 80 dB(A).[2]
  • Applying it to classroom noise for pupils. The Regulations concern noise at work and exclude nuisance noise.[2]
  • Forgetting the peak values. Regulation 4 sets separate C-weighted peak limits for each level.[1]

How it is checked

The employer assesses by observing work practices, using manufacturers' information on equipment noise and, if necessary, measuring noise.[1] The assessment must be reviewed regularly and whenever it may be out of date.[1] HSE publishes guidance on the Regulations.[2] Enforcement and the facts of a specific workplace are for the employer and the regulator; check with HSE or a legal adviser.

FAQ

What are the noise action values at work?

Lower 80 dB(A) and upper 85 dB(A) daily or weekly personal exposure, with an exposure limit value of 87 dB(A).[1][2]

Do the Regulations cover Northern Ireland?

HSE describes them as applying in Great Britain.[2]

Do they apply to restaurants, kitchens and sports halls?

They apply to any workplace where employees' noise exposure reaches the values, and a risk assessment decides whether it does.[1]

WorkSpace Acoustics surveys and installs acoustic treatment; contact the team to discuss a room.

Sources

  1. The Control of Noise at Work Regulations 2005 (SI 2005/1643), regulations 3 to 9. legislation.gov.uk, SI 2005/1643. Accessed November 2026.
  2. Control of Noise at Work Regulations: Regulations. Health and Safety Executive, updated 6 March 2025. Accessed November 2026.
  3. Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.
Expert acoustic consultancy and installation for schools, businesses and restaurants across the UK. Specialists in SEN environments.
A specialist division of: Presentation Spaces Group

COMPANY

About
Why Acoustics
Contact Us
Privacy Policy
Glossary
Acoustics statistics

SECTORS

Schools
Businesses
Restaurants

SERVICES

Acoustic Surveys
Acoustic Design
Installation
© 2026 WorkSpace Acoustics Ltd. All rights reserved.
Product images courtesy of Presentation Spaces Group (used with permission)