What is dB(A) and A-weighting?
dB(A) is a sound level in decibels that has been A-weighted: adjusted by a standard weighting that approximates how sensitive the ear is at different frequencies. It gives one overall figure, so a meter can report a single number. BB93 and HSE both state their limits in A-weighted terms.[1][2][3]
Key points
- The sensitivity of the ear depends on frequency, and sound level meters are fitted with a weighting network that approximates it, giving a single figure in dBA.[1]
- The A-weighting removes 16.1 dB from the 125 Hz octave band and adds 1.2 dB at 2 kHz.[1]
- The "A" is often moved into the descriptor, so 55 dB(A) can be quoted as 55 dB LAeq.[1]
- HSE sets 80 dB(A) and 85 dB(A) daily or weekly average exposure action levels for workers, and WHO recommends less than 35 dB(A) in classrooms.[3][4]
How it works
The ear is less sensitive to low frequencies than to mid frequencies at the same sound pressure, so an unweighted level would overstate the effect of low-frequency rumble. The A-weighting network corrects for this.[1]
The numbers
The Institute of Acoustics and the Association of Noise Consultants give these A-weighting corrections for octave band centre frequencies:[1]
- 63 Hz: minus 26.2 dB.[1]
- 125 Hz: minus 16.1 dB.[1]
- 250 Hz: minus 8.6 dB.[1]
- 500 Hz: minus 3.2 dB.[1]
- 1 kHz: 0 dB.[1]
- 2 kHz: plus 1.2 dB, and at 4 kHz plus 1.0 dB.[1]
To calculate an A-weighted level from octave band data, add each correction to its band level and combine the results logarithmically using the equation for adding decibels.[1]
In schools and SEN settings
BB93's indoor ambient noise limits are A-weighted: 35 dB LAeq,30mins for a new build primary or secondary classroom, 40 dB for refurbishment, and 30 dB new build or 35 dB refurbishment for a teaching space intended specifically for students with special hearing and communication needs.[2] The WHO guideline for classrooms is also an A-weighted figure, below 35 dB(A).[4] Because the weighting discounts low frequencies, a classroom can meet an A-weighted limit and still contain low-frequency noise, so the limit is read together with the room's other criteria and not on its own.[1][2]
Worked example
These figures are illustrative. A room has a measured level of 60 dB in the 125 Hz band and 50 dB in the 1 kHz band, and nothing else of note.[1] A-weighted: 125 Hz becomes 60 – 16.1 = 43.9 dB; 1 kHz stays 50 dB.[1] Combined: 10 lg (10^4.39 + 10^5.0) = 10 lg (24,547 + 100,000) = 10 lg 124,547 = 50.95 dB, so about 51 dB(A).[1] The loud 125 Hz band contributes little to the single figure because of the weighting.[1]
What people get wrong
- Assuming dB and dB(A) are interchangeable. The same sound has a different value in each, and the difference depends on its frequency content.[1]
- Treating a dB(A) figure as a complete description. BB93 pairs the A-weighted level with a descriptor and a period (LAeq,30mins) so that a result can be compared with a limit.[2]
- Applying workplace thresholds to classrooms. HSE's 80 dB(A) and 85 dB(A) levels protect workers' hearing and are not teaching-comfort targets.[3]
How it is measured
A sound level meter applies the A-weighting electronically. IEC 61672-1 specifies the performance of sound level meters, with class 1 and class 2 performance categories where class 2 acceptance limits are greater than or equal to those of class 1.[5]
FAQ
What does the A in dB(A) stand for?
It names the A-weighting curve, which approximates the frequency response of the ear.[1]
What is 85 dB(A) in workplace rules?
It is the daily or weekly average exposure at which employers must provide hearing protection and hearing protection zones.[3]
Do classroom limits use dB(A)?
Yes. BB93 and the WHO classroom guideline are A-weighted.[2][4]
Can I convert dB to dB(A)?
Only with band-by-band data, applying the corrections above and combining the results.[1]
WorkSpace Acoustics surveys and installs acoustic treatment; contact the team to talk about a room.
Sources
- Acoustics of Schools: a design guide. Institute of Acoustics and Association of Noise Consultants, November 2015. Accessed November 2026.
- Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.
- Noise at work: Regulations. Health and Safety Executive, no date shown on the page. Accessed November 2026.
- Noise. World Health Organization Regional Office for Europe, no date shown on the page. Accessed November 2026.
- IEC 61672-1:2013 Electroacoustics: Sound level meters, Part 1: Specifications. International Electrotechnical Commission, September 2013. Accessed November 2026.