What is dB(A) and A-weighting?

dB(A) is a sound level in decibels that has been A-weighted: adjusted by a standard weighting that approximates how sensitive the ear is at different frequencies. It gives one overall figure, so a meter can report a single number. BB93 and HSE both state their limits in A-weighted terms.[1][2][3]

Key points

  • The sensitivity of the ear depends on frequency, and sound level meters are fitted with a weighting network that approximates it, giving a single figure in dBA.[1]
  • The A-weighting removes 16.1 dB from the 125 Hz octave band and adds 1.2 dB at 2 kHz.[1]
  • The "A" is often moved into the descriptor, so 55 dB(A) can be quoted as 55 dB LAeq.[1]
  • HSE sets 80 dB(A) and 85 dB(A) daily or weekly average exposure action levels for workers, and WHO recommends less than 35 dB(A) in classrooms.[3][4]

How it works

The ear is less sensitive to low frequencies than to mid frequencies at the same sound pressure, so an unweighted level would overstate the effect of low-frequency rumble. The A-weighting network corrects for this.[1]

The numbers

The Institute of Acoustics and the Association of Noise Consultants give these A-weighting corrections for octave band centre frequencies:[1]

  • 63 Hz: minus 26.2 dB.[1]
  • 125 Hz: minus 16.1 dB.[1]
  • 250 Hz: minus 8.6 dB.[1]
  • 500 Hz: minus 3.2 dB.[1]
  • 1 kHz: 0 dB.[1]
  • 2 kHz: plus 1.2 dB, and at 4 kHz plus 1.0 dB.[1]

To calculate an A-weighted level from octave band data, add each correction to its band level and combine the results logarithmically using the equation for adding decibels.[1]

In schools and SEN settings

BB93's indoor ambient noise limits are A-weighted: 35 dB LAeq,30mins for a new build primary or secondary classroom, 40 dB for refurbishment, and 30 dB new build or 35 dB refurbishment for a teaching space intended specifically for students with special hearing and communication needs.[2] The WHO guideline for classrooms is also an A-weighted figure, below 35 dB(A).[4] Because the weighting discounts low frequencies, a classroom can meet an A-weighted limit and still contain low-frequency noise, so the limit is read together with the room's other criteria and not on its own.[1][2]

Worked example

These figures are illustrative. A room has a measured level of 60 dB in the 125 Hz band and 50 dB in the 1 kHz band, and nothing else of note.[1] A-weighted: 125 Hz becomes 60 – 16.1 = 43.9 dB; 1 kHz stays 50 dB.[1] Combined: 10 lg (10^4.39 + 10^5.0) = 10 lg (24,547 + 100,000) = 10 lg 124,547 = 50.95 dB, so about 51 dB(A).[1] The loud 125 Hz band contributes little to the single figure because of the weighting.[1]

What people get wrong

  • Assuming dB and dB(A) are interchangeable. The same sound has a different value in each, and the difference depends on its frequency content.[1]
  • Treating a dB(A) figure as a complete description. BB93 pairs the A-weighted level with a descriptor and a period (LAeq,30mins) so that a result can be compared with a limit.[2]
  • Applying workplace thresholds to classrooms. HSE's 80 dB(A) and 85 dB(A) levels protect workers' hearing and are not teaching-comfort targets.[3]

How it is measured

A sound level meter applies the A-weighting electronically. IEC 61672-1 specifies the performance of sound level meters, with class 1 and class 2 performance categories where class 2 acceptance limits are greater than or equal to those of class 1.[5]

FAQ

What does the A in dB(A) stand for?

It names the A-weighting curve, which approximates the frequency response of the ear.[1]

What is 85 dB(A) in workplace rules?

It is the daily or weekly average exposure at which employers must provide hearing protection and hearing protection zones.[3]

Do classroom limits use dB(A)?

Yes. BB93 and the WHO classroom guideline are A-weighted.[2][4]

Can I convert dB to dB(A)?

Only with band-by-band data, applying the corrections above and combining the results.[1]

WorkSpace Acoustics surveys and installs acoustic treatment; contact the team to talk about a room.

Sources

  1. Acoustics of Schools: a design guide. Institute of Acoustics and Association of Noise Consultants, November 2015. Accessed November 2026.
  2. Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.
  3. Noise at work: Regulations. Health and Safety Executive, no date shown on the page. Accessed November 2026.
  4. Noise. World Health Organization Regional Office for Europe, no date shown on the page. Accessed November 2026.
  5. IEC 61672-1:2013 Electroacoustics: Sound level meters, Part 1: Specifications. International Electrotechnical Commission, September 2013. Accessed November 2026.
Expert acoustic consultancy and installation for schools, businesses and restaurants across the UK. Specialists in SEN environments.
A specialist division of: Presentation Spaces Group

COMPANY

About