What is LAeq?
LAeq is the equivalent continuous A-weighted sound pressure level: the level of a steady sound that would deliver the same A-weighted sound energy as the actual fluctuating sound over a stated period. BB93 sets its indoor ambient noise limits as LAeq,30mins, for example 35 dB for a new build classroom.[1][2]
Key points
- LAeq is an energy average, and it is the most widely used unit for time-varying sound.[1]
- The period matters: LAeq,T carries the duration T, and BB93 uses 30 minutes, written LAeq,30mins.[1][2]
- LAeq is not affected by the sound level meter time constant, whereas LAmax and LAmin can be measured fast or slow.[1]
- LA90,T is the level exceeded for 90% of the period, often used to represent the background level.[1]
How it works
Most sounds are not steady, so a single reading is not enough. The Institute of Acoustics and the Association of Noise Consultants describe LAeq,T as a level that would deliver the same A-weighted sound energy over the period T as the real signal.[1] Because it averages energy, a short loud event raises LAeq far more than a long quiet period lowers it.
Other descriptors sit beside it. LAmax,T and LAmin,T are the maximum and minimum levels in the period. Percentile levels are the level exceeded for a percentage of the period: LA1,T for 1%, usually a typical maximum; LA10,T for 10%, often used for road traffic; and LA90,T for 90%, often used for the background level.[1] Percentile levels must be measured with the fast (125 ms) time constant.[1]
The numbers
- BB93 indoor ambient noise limit, new build, nursery, primary or secondary classroom: 35 dB LAeq,30mins; refurbishment: 40 dB.[2]
- Open plan teaching area: 40 dB LAeq,30mins new build, 45 dB refurbishment.[2]
- Teaching space for students with special hearing and communication needs: 30 dB LAeq,30mins new build, 35 dB refurbishment.[2]
- SEN calming room: 35 dB LAeq,30mins for both new build and refurbishment.[2]
- External noise at the boundary of outdoor teaching and recreation areas for new schools: 60 dB LAeq,30min as an upper limit.[1]
In schools and SEN settings
BB93 describes the indoor ambient noise level as noise from outside the school and from building services such as ventilation, measured in an unoccupied room, and it excludes noise from teaching activities and classroom equipment.[2] The limit therefore describes the room's background before anyone arrives, which is the condition against which speech has to be heard.[2][1] For rooms for pupils with special hearing and communication needs the limit is 30 dB new build and 35 dB refurbishment, and the same room carries a mid-frequency reverberation time of 0.4 s.[2]
Worked example
These figures are illustrative. Suppose a 30 minute survey has 29 minutes at 33 dB and 1 minute at 50 dB.[1] Energy average: 10 lg [ (29 x 10^3.3 + 1 x 10^5.0) / 30 ] = 10 lg [ (29 x 1,995 + 100,000) / 30 ] = 10 lg [ (57,855 + 100,000) / 30 ] = 10 lg 5,262 = 37.2 dB.[1] One minute of louder noise lifts LAeq,30min above 35 dB, while LA90 would stay near 33 dB.[1]
What people get wrong
- Reading LAeq as the typical level. It is an energy average and is pulled up by brief loud events; LA90 is the descriptor often used for the background.[1]
- Comparing results from different periods. A figure only compares with a limit when its time period matches, as with BB93's 30 minutes.[2]
- Mixing in classroom activity. BB93's indoor ambient noise level excludes activity noise and equipment noise.[2]
How it is measured
A sound level meter that integrates over the period gives LAeq directly. IEC 61672-1 specifies integrating-averaging sound level meters that measure time-averaged, frequency-weighted sound levels.[3] BB93 measurement is in a finished, unoccupied room, with natural ventilators or windows open as needed to provide ventilation and mechanical plant at its normal duty.[2]
FAQ
What does the 30min in LAeq,30min mean?
It is the averaging period of 30 minutes over which the energy average is taken.[1][2]
Is LAeq the same as LA90?
No. LAeq is an energy average, while LA90 is the level exceeded for 90% of the period.[1]
What LAeq does a classroom need?
BB93 gives 35 dB LAeq,30mins for most new build classrooms and 40 dB for refurbishment.[2]
Does the time constant change LAeq?
No. LAeq is not affected by the sound level meter time constant.[1]
WorkSpace Acoustics surveys and installs acoustic treatment; contact the team to talk about a room.
Sources
- Acoustics of Schools: a design guide. Institute of Acoustics and Association of Noise Consultants, November 2015. Accessed November 2026.
- Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.
- IEC 61672-1:2013 Electroacoustics: Sound level meters, Part 1: Specifications. International Electrotechnical Commission, September 2013. Accessed November 2026.