What is ISO 3382?

ISO 3382 is the series of international standards for measuring room acoustic parameters. Part 1 covers performance spaces, part 2 covers reverberation time in ordinary rooms such as classrooms, and part 3 covers open plan offices. UK school acoustic guidance refers to part 2 for measuring reverberation time on site.[1][2]

Key points

  • ISO 3382-2:2008 specifies the procedure, apparatus, number of measurement positions, data evaluation and test report for reverberation time in ordinary rooms.[1]
  • Part 1 (2009) covers performance spaces; part 3 (2022) covers open plan offices.[3][4]
  • Part 2 was last reviewed and confirmed in 2022, so it remains current.[1]
  • The Institute of Acoustics design guide refers to ISO 3382-2 for measuring reverberation time, saying that as a minimum the engineering method should be used when determining total absorption in a room.[2]

How it works

Each part has its own scope. Part 2 gives methods for measuring reverberation time in ordinary rooms, and its results can be used to correct other acoustic measurements and to compare a room with its reverberation time requirement.[1] Part 1 specifies methods for reverberation time and other room acoustical parameters in performance spaces, using modern digital measurement of impulse responses.[3] Part 3 specifies a method for unoccupied open plan offices.[4]

The standards are paid documents and this page uses only the catalogue abstracts. Part 1 is shown as published in 2009 and due for revision, with a replacement under development.[3]

ISO 3382-3: open plan offices

Part 3 describes a group of single-number quantities that show the room acoustic performance of an open plan office when one person is speaking. They focus on the spatial decay of speech, while part 2 focuses on the temporal decay of sound.[4] This is why it is the reference for office-style spaces, not for classrooms. The design guide points to part 3 for alternative descriptors relevant to speech in rooms where reverberation time is not an accurate descriptor, such as rooms with a very uneven shape or uneven absorption.[2]

The numbers

BB93 sets the limit that a part 2 measurement is compared with.[5]

  • Tmf is the arithmetic average of the reverberation times in the 500 Hz, 1 kHz and 2 kHz octave bands, or of the one-third octave bands from 400 Hz to 2.5 kHz.[5]
  • For rooms intended specifically for pupils with special hearing or communication needs, the average runs over the 125 Hz to 4 kHz octave bands.[5]
  • For modelling a sports hall, the design guide uses at least two source positions and six receiver positions at 1.5 m above the floor and at least 1 m from walls.[2]

In schools and SEN settings

BB93 says pre-completion testing should follow the Association of Noise Consultants testing guide, and the design guide refers to ISO 3382-2 for reverberation measurement.[2][5] A school receiving a test report can therefore expect reverberation times by octave band and a Tmf to compare with table 6 of BB93.[5]

For rooms for pupils with special hearing or communication needs, the band range widens to 125 Hz to 4 kHz, so a report that only lists 500 Hz to 2 kHz would not show the figure BB93 asks for.[5]

Worked example

An illustrative classroom measures 0.72 s at 500 Hz, 0.66 s at 1 kHz and 0.60 s at 2 kHz (invented figures).[5] Tmf = (0.72 + 0.66 + 0.60) / 3 = 0.66 s.[5] That passes the refurbishment limit of 0.8 s for a primary classroom and fails the new build limit of 0.6 s.[5]

What people get wrong

  • Saying "ISO 3382" without the part. Part 2 covers ordinary rooms; part 3 covers open plan offices.[1][4]
  • Using part 3 for a classroom. It is for unoccupied open plan offices.[4]
  • Treating reverberation time as a full measure of speech clarity. The design guide says it may not be accurate in rooms with a non-uniform sound field.[2]

How it is measured

Part 2 specifies the measurement procedure, the apparatus, the required number of measurement positions and the evaluation of the data, and it sets out how the test report is presented.[1] The design guide says the reverberation time should be measured in octave bands when it is used to determine total absorption.[2] For rooms of a very uneven shape, additional descriptors may be needed.[2]

FAQ

Which part of ISO 3382 is used for classrooms?

Part 2, reverberation time in ordinary rooms.[1][2]

Is ISO 3382 the same as BB93?

No. ISO 3382 is a measurement standard. BB93 sets the limits that the measured value is compared with.[5]

Is ISO 3382 free to read?

No. The standards are sold by ISO; the catalogue pages give abstracts.[1]

WorkSpace Acoustics surveys and installs acoustic treatment for schools; contact the team to discuss a room.

Sources

  1. ISO 3382-2:2008 Acoustics: Measurement of room acoustic parameters, Part 2: Reverberation time in ordinary rooms. International Organization for Standardization, June 2008, confirmed 2022. Accessed November 2026.
  2. Acoustics of Schools: a design guide. Institute of Acoustics and Association of Noise Consultants, November 2015. Accessed November 2026.
  3. ISO 3382-1:2009 Acoustics: Measurement of room acoustic parameters, Part 1: Performance spaces. International Organization for Standardization, June 2009, confirmed 2021. Accessed November 2026.
  4. ISO 3382-3:2022 Acoustics: Measurement of room acoustic parameters, Part 3: Open plan offices. International Organization for Standardization, January 2022. Accessed November 2026.
  5. Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.
Expert acoustic consultancy and installation for schools, businesses and restaurants across the UK. Specialists in SEN environments.
A specialist division of: Presentation Spaces Group

COMPANY

About
Why Acoustics
Contact Us
Privacy Policy
Glossary
Acoustics statistics

SECTORS

Schools
Businesses
Restaurants

SERVICES

Acoustic Surveys
Acoustic Design
Installation
© 2026 WorkSpace Acoustics Ltd. All rights reserved.
Product images courtesy of Presentation Spaces Group (used with permission)