What is Approved Document E (Building Regulations Part E)?

Approved Document E is the Government's statutory guidance on resistance to the passage of sound under the Building Regulations 2010 in England. For schools, Requirement E4 is the law, and section 8 of the document says the normal way to satisfy it is to meet the sound insulation, reverberation time and ambient noise values in BB93.[1][2]

Key points

  • Part E of Schedule 1 to the Building Regulations 2010 is law. Approved Document E is guidance on how to meet it.[2][3]
  • Requirement E4 says each room or space in a school building must have acoustic conditions and insulation against disturbance by noise appropriate to its intended use.[3]
  • Section 8 of the document says the normal way of satisfying E4 is to meet the values in BB93.[2]
  • The guidance applies to building work in England; Scotland has its own building standards.[2][4]

How it works

Regulation 4 of the Building Regulations 2010 says building work must comply with the applicable requirements in Schedule 1.[3] Part E of Schedule 1 has four requirements. E1 to E3 cover homes and residential rooms, and E4 covers schools.[2][3]

Approved Document E is one of a series approved by the Secretary of State to give practical guidance. It says there is no obligation to adopt any solution it contains if the requirement is met another way.[2] For schools its section 8 is one paragraph long and hands the detail to BB93.[2] In the Building Regulations, a "school" has the meaning in section 4 of the Education Act 1996.[2]

Building Regulations 2010

The Building Regulations 2010 (SI 2010/2214) are the statutory instrument that contains Requirement E4 in Schedule 1.[3] Regulation 4 applies Schedule 1 to building work, and regulation 6 applies E4 where a building has a material change of use to a public building that is or contains a school.[2][3]

The numbers

Approved Document E does not itself list school acoustic values. BB93 does, and this page gives the pattern only.[5]

  • E4 applies to new build, including extensions and prefabricated buildings, and to a material change of use into a school.[5]
  • BB93 says E4 is exempt for refurbishment of existing school buildings and for temporary buildings in place for up to 28 days.[5]
  • Buildings that stay in place longer than 28 days must comply with the Building Regulations.[5]

In schools and SEN settings

BB93 says pupils with special educational needs are generally more sensitive to the acoustic environment, and its tables reflect that with shorter reverberation times, higher insulation and lower ambient noise for their rooms.[5] The figures for rooms for pupils with special hearing or communication needs are described as a starting point.[5] Approved Document E adds nothing further: the SEN-specific values live in BB93.[2][5]

Worked example

An illustrative school adds a new classroom block and refurbishes an older one. The new block is new build, so E4 applies and the BB93 new build values are the normal means of satisfying it.[2][5] BB93's table shows E4 as exempt for refurbishment of the older block, but the School Premises Regulations still apply to the school as a whole.[5]

What people get wrong

  • Treating Approved Document E as the law. The requirement in Schedule 1 is the law. The document is guidance, and another solution is allowed if it meets the requirement.[2][3]
  • Assuming it applies across the UK. The guidance is for building work in England.[2]
  • Assuming Part E is only about homes. E4 covers schools.[3]

How it is checked

Before construction, intention to comply is shown to the building control body with plans, construction details, specifications and calculations. BB93 says the Building Regulations contain no requirement for acoustic commissioning of schools, although it is strongly recommended for contractual purposes.[5] Check with the local authority or a legal adviser for a specific project.

FAQ

What is Requirement E4?

It is the part of Schedule 1 that requires each room or space in a school building to have acoustic conditions and insulation against noise appropriate to its intended use.[3]

Does Approved Document E apply in Scotland, Wales or Northern Ireland?

The document gives guidance for work in England.[2] Scotland has separate building standards, covered on its own page.[4]

Is BB93 part of Approved Document E?

No. Approved Document E refers to BB93 in section 8 and says meeting BB93 is the normal way to satisfy E4.[2]

WorkSpace Acoustics surveys and installs acoustic treatment for schools; contact the team to discuss a room.

Sources

  1. Resistance to sound: Approved Document E. GOV.UK (Ministry of Housing, Communities and Local Government), published 4 March 2015. Accessed November 2026.
  2. Approved Document E: resistance to the passage of sound. Ministry of Housing, Communities and Local Government, 2003 edition incorporating 2004, 2010 and 2013 amendments. Accessed November 2026.
  3. The Building Regulations 2010, regulation 4 and Schedule 1 Part E. legislation.gov.uk, SI 2010/2214. Accessed November 2026.
  4. Building standards technical handbook: non-domestic, Section 5 Noise. Scottish Government, April 2026. Accessed November 2026.
  5. Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.
Expert acoustic consultancy and installation for schools, businesses and restaurants across the UK. Specialists in SEN environments.
A specialist division of: Presentation Spaces Group

COMPANY

About