What is sound insulation?

Sound insulation is the reduction in sound passing from one room to another through walls, floors, doors and windows. Airborne sound insulation is rated as a level difference in decibels, DnT,w, where a higher number is better. BB93 sets minimum values between school rooms, for example 45 dB between two classrooms in new build.[1][2]

Key points

  • Sound in one room makes surrounding surfaces vibrate, and that vibration is transmitted through the structure and radiated into other rooms.[1]
  • Airborne insulation between rooms is rated by DnT,w, a level difference, so a higher value means better insulation; impact insulation is the opposite, a level where lower is better.[1]
  • Sound insulation measured on site includes flanking transmission through connected walls, floors and ceilings, so it is usually lower than laboratory values.[1]
  • BB93 sets minimum DnT,w values by the noise made in the source room and the noise tolerance of the receiving room.[2]

How it works

The design guide describes the route. Speech, audio-visual systems and musical instruments are airborne sound sources; the sound causes walls, floors and ceilings to vibrate, and that vibration is radiated into receiving rooms.[1] The greater the airborne insulation between two rooms, the lower the level in the receiving room.[1]

Insulation is not only the separating wall. The level difference depends on the direct transmission through the separating element, flanking transmission through the elements around it, the wall and floor dimensions and the reverberation time of the receiving room.[1] That is why the sound reduction index R of an element measured in a laboratory is usually higher than the apparent value R' on site.[1]

The numbers

BB93 minimum airborne sound insulation DnT,w between spaces:[2]

  • Source room with average activity noise, receiving room with medium noise tolerance (for example classroom to classroom): 45 dB new build, 40 dB refurbishment.[2]
  • Source room with average activity noise, receiving room with low noise tolerance (for example a classroom to a teaching space for students with special hearing and communication needs): 50 dB new build, 40 dB refurbishment.[2]
  • Doorset between a teaching space and another occupied room where an interconnecting door is essential: at least 35 dB Rw, in a wall with a composite rating of at least 45 dB Rw.[2]

The design assessment of DnT,w between two rooms is carried out in both directions.[2]

In schools and SEN settings

BB93 classifies rooms by the noise they make and the noise they tolerate, and the insulation requirement follows from the pair. A teaching space intended specifically for students with special hearing and communication needs is a low noise tolerance receiving room, so its walls need more insulation than an ordinary classroom: 50 dB DnT,w from a neighbouring average-noise classroom in new build, against 45 dB between two ordinary classrooms.[2] A SEN calming room is classed as a high activity noise source with low noise tolerance in the receiving role.[2]

Worked example

These figures are illustrative. Two new build classrooms share a wall tested at a DnT,w of 42 dB.[2] The BB93 minimum for average-noise source to medium-tolerance receiving room is 45 dB new build, so the wall is 3 dB short.[2] The same test result would exceed the 40 dB refurbishment value.[2] If the speech in the source room is 65 dB, the level in the receiving room is roughly 65 – 42 = 23 dB, since the level difference is the source level minus the receiving level and ignoring the reverberation correction.[1]

What people get wrong

  • Using laboratory values on site. On-site results include flanking transmission and workmanship, so they are usually lower.[1]
  • Mixing up the two directions. For airborne insulation higher is better; for impact sound insulation a lower number is better.[1]
  • Expecting absorbers to insulate. Absorption and insulation are different properties.[1]

How it is measured

ISO 16283-1 specifies procedures to determine airborne sound insulation between two rooms using sound pressure measurements, for room volumes from 10 m3 to 250 m3 in the frequency range 50 Hz to 5,000 Hz.[3] The results are rated into a single number using ISO 717-1; BB93 sets the weighted standardized level difference DnT,w.[3][1]

FAQ

What is DnT,w?

The weighted standardized level difference, a single-number rating of airborne sound insulation between two rooms measured on site.[1]

Does a higher DnT,w mean better insulation?

Yes, for airborne sound insulation.[1]

What does BB93 require between two classrooms?

At least 45 dB DnT,w in new build and 40 dB in refurbishment, where the source has average activity noise and the receiving room medium tolerance.[2]

Is sound insulation the same as acoustic treatment?

No. Insulation limits transmission between rooms, while absorption controls reflections within a room.[1]

WorkSpace Acoustics surveys and installs acoustic treatment; contact the team to talk about a room.

Sources

  1. Acoustics of Schools: a design guide. Institute of Acoustics and Association of Noise Consultants, November 2015. Accessed November 2026.
  2. Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.
  3. ISO 16283-1:2014 Acoustics: Field measurement of sound insulation in buildings and of building elements, Part 1: Airborne sound insulation. International Organization for Standardization, February 2014. Accessed November 2026.
Expert acoustic consultancy and installation for schools, businesses and restaurants across the UK. Specialists in SEN environments.
A specialist division of: Presentation Spaces Group

COMPANY

About
Why Acoustics
Contact Us
Privacy Policy
Glossary
Acoustics statistics

SECTORS

Schools
Businesses
Restaurants

SERVICES

Acoustic Surveys
Acoustic Design
Installation
© 2026 WorkSpace Acoustics Ltd. All rights reserved.
Product images courtesy of Presentation Spaces Group (used with permission)