What is RT60?

RT60 is the abbreviation for reverberation time based on a 60 dB drop: the time in seconds that sound in a room takes to fade by 60 dB after the source stops.[1] The value varies with frequency, so test reports give it per octave band, and BB93 summarises it as Tmf for schools.[2]

Key points

  • The "60" is the size of the drop: a fall of 60 dB, or to one millionth of the original sound energy.[1]
  • RT60 is a time in seconds, and the same room has a different value in each frequency band.[1]
  • BB93 sets school limits on the mid-frequency average (Tmf), not on one all-frequency figure.[2]
  • RT60 is the same quantity as the reverberation time that BB93 and the Institute of Acoustics design guide write as T.[1][2]

How it works

When a source stops, the sound in a room does not vanish. It is reflected from the surfaces and each reflection loses a little energy to absorption. The reverberation time is the measure of how fast that decay happens, and it is defined as the time for the reverberant energy to fall to one millionth of its starting intensity, which corresponds to a 60 dB reduction in level.[1]

Because absorption changes with frequency, the time is normally given in frequency bands rather than as one number.[1]

The numbers

BB93 expresses its school limits (new build and refurbishment) as Tmf, the average of the times in the 500 Hz, 1 kHz and 2 kHz octave bands (or the one-third octave bands from 400 Hz to 2.5 kHz).[2] For rooms specifically for pupils with special hearing or communication needs, the average is taken across the 125 Hz to 4 kHz octave bands instead.[2] Typical maximum Tmf values for new build are 0.6 s in a primary classroom and 0.8 s in a secondary classroom.[2]

In schools and SEN settings

Schools need one figure a designer can check against a limit, which is why BB93 uses Tmf. For a room used by a pupil with a hearing impairment the picture is wider, and the design guide records the British Association of Teachers of the Deaf criterion of 0.4 s or less across 125 Hz to 4000 Hz.[1] BB93 sets the matching new build limit at an average of 0.4 s with no octave band above 0.6 s.[2] A survey report for such a room should therefore show the result in every band, not only a headline figure.

Neither BB93 nor the design guide uses the label RT60; both say reverberation time, so a school specification should be read as asking for the same quantity.[1][2]

Worked example

The 60 dB in the definition makes the decay rate easy to work out.[1] If a classroom has a reverberation time of 0.6 s, its sound level falls at 60 dB ÷ 0.6 s = 100 dB per second.[1] A hall with a time of 2.0 s falls at 30 dB per second, which is why a shout or a clatter lingers.[1] These sums only restate the definition and are not a measured room.

What people get wrong

  • Treating RT60 as one fixed number for a room. It changes by frequency band, and by whether the room is furnished and occupied; BB93 values apply to finished, furnished, unoccupied rooms.[2]
  • Comparing a headline figure with a limit set on another basis. BB93 limits are Tmf values, and the SEN criteria use a wider band average.[2]
  • Assuming the calculation equals the measurement. The design guide warns that the standard formula is only representative of diffuse sound fields and should be used with caution.[1]

How it is measured

ISO 3382-2 specifies the measurement of reverberation time in ordinary rooms, including the procedure, the apparatus, the number of measurement positions and the content of the test report.[3] BB93 refers to the Association of Noise Consultants testing guide for measuring completed school spaces.[2]

FAQ

What does the 60 in RT60 mean?

It is the 60 dB drop in sound level over which the decay time is defined.[1]

Is RT60 the same as reverberation time?

Yes. The Institute of Acoustics guide defines reverberation time as the time for a 60 dB reduction, and BB93 uses the same quantity.[1][2]

What RT60 does a school classroom need?

BB93 sets maximum Tmf values by room type, for example 0.6 s for a new build primary classroom and 0.4 s averaged across 125 Hz to 4 kHz for rooms for pupils with special hearing needs.[2]

WorkSpace Acoustics surveys and installs acoustic treatment; contact the team to arrange a room survey.

Sources

  1. Acoustics of Schools: a design guide. Institute of Acoustics and Association of Noise Consultants, November 2015. Accessed November 2026.
  2. Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.
  3. ISO 3382-2:2008 Acoustics: Measurement of room acoustic parameters, Part 2: Reverberation time in ordinary rooms. International Organization for Standardization, June 2008, confirmed 2022. Accessed November 2026.
Expert acoustic consultancy and installation for schools, businesses and restaurants across the UK. Specialists in SEN environments.
A specialist division of: Presentation Spaces Group

COMPANY

About
Why Acoustics
Contact Us
Privacy Policy
Glossary
Acoustics statistics

SECTORS

Schools
Businesses
Restaurants

SERVICES

Acoustic Surveys
Acoustic Design
Installation
© 2026 WorkSpace Acoustics Ltd. All rights reserved.
Product images courtesy of Presentation Spaces Group (used with permission)