What is an acoustic survey?
An acoustic survey is a set of measurements of how a building or site performs acoustically. For existing school buildings the Institute of Acoustics guide suggests, as a minimum, sound insulation tests across each type of partition and floor, a reverberation time test in each type of room, and indoor ambient noise levels on each facade.[1]
Key points
- A survey establishes the existing sound insulation, indoor ambient noise level and reverberation time so acoustic targets can be put in context.[1]
- The design guide's minimum set is two airborne sound insulation tests per partition type, two airborne and two impact tests per floor type, one reverberation time test per room type, and ambient noise in at least two rooms on each facade.[1]
- Testing follows the Association of Noise Consultants Good Practice Guide: Acoustic Testing of Schools.[1]
- A site noise survey for a new school is measured during school hours to quantify the representative LAeq,30min.[1]
How it works
The design guide describes why existing performance matters. Where an existing element or space is to be converted or upgraded, knowing its prevailing performance helps put acoustic targets into context.[1] It lists a minimum that could be carried out to get a representative data set, while noting that individual site conditions may require a different approach.[1]
The measurements it names each have their own standard. Reverberation time in ordinary rooms follows ISO 3382-2, and airborne sound insulation between rooms follows ISO 16283-1.[2][3] Levels are measured with a sound level meter specified in IEC 61672-1.[4]
The numbers
The design guide's suggested minimum for an existing school building:[1]
- At least two airborne sound insulation tests across each type of partition.[1]
- At least two airborne and two impact sound transmission tests across each type of floor.[1]
- At least one reverberation time test in each type of room.[1]
- Indoor ambient noise levels in at least two rooms on each facade.[1]
A site survey for a new school: measure during school hours over a suitable period, include noisy events such as peak-hour road traffic, exclude occasional school events such as lawn mowing and drop-off traffic.[1]
In schools and SEN settings
The results are compared with BB93 values for the room type: for example indoor ambient noise of 35 dB LAeq,30mins for a new build classroom and 40 dB for refurbishment, and 30 dB new build and 35 dB refurbishment for a teaching space intended specifically for students with special hearing and communication needs.[5] Reverberation time is compared as Tmf, 0.6 s new build and 0.8 s refurbishment for a primary classroom.[5] The design guide notes that in some circumstances testing may be unnecessary or of limited value, for example when a poorly sealed service penetration would prevent measuring a partition's potential insulation, and a design appraisal may be more appropriate.[1] It also says a partition already meeting its target, or surfaces already meeting reverberation targets, may need no acoustic change.[1]
Worked example
These figures are illustrative. A school block has three types of partition and two types of floor. Using the design guide's minimum: 3 x 2 = 6 airborne tests across partitions, 2 x 2 = 4 airborne and 2 x 2 = 4 impact tests across floors, so 14 sound insulation tests.[1] Add one reverberation time test for each room type, and ambient noise in two rooms on each facade.[1]
What people get wrong
- Treating the minimum as a rule. The guide says it is a minimum to obtain a representative set and that site conditions may require a different approach.[1]
- Testing without checking the flanking paths. On-site insulation includes flanking transmission, and pre-existing flanking elements may not be evident without intrusive investigation.[1]
- Mixing external and internal levels. The site noise survey and the indoor ambient noise level are different quantities.[1][5]
How it is measured
The instruments and standards are the ones above: a sound level meter to IEC 61672-1, reverberation time to ISO 3382-2 and airborne sound insulation to ISO 16283-1.[4][2][3] Notes by a competent person on subjective impressions, such as boomy transmitted sound, rattling fixtures or flanking paths, help inform the design.[1]
FAQ
What does an acoustic survey measure?
Sound insulation, indoor ambient noise and reverberation time in an existing building, and external noise at a site.[1]
Is a survey the same as pre-completion testing?
Not in the same sense: BB93 section 2.3 describes pre-completion testing of finished work, while the design guide's minimum procedure applies to existing buildings.[5][1]
Who should do testing in schools?
BB93 says pre-completion testing should be by a specialist acoustic consultant following the Association of Noise Consultants guide.[5]
Can a survey be unnecessary?
The design guide says testing may be unnecessary or of limited value in some circumstances.[1]
WorkSpace Acoustics surveys and installs acoustic treatment; contact the team to talk about a room.
Sources
- Acoustics of Schools: a design guide. Institute of Acoustics and Association of Noise Consultants, November 2015. Accessed November 2026.
- ISO 3382-2:2008 Acoustics: Measurement of room acoustic parameters, Part 2: Reverberation time in ordinary rooms. International Organization for Standardization, June 2008, confirmed 2022. Accessed November 2026.
- ISO 16283-1:2014 Acoustics: Field measurement of sound insulation in buildings and of building elements, Part 1: Airborne sound insulation. International Organization for Standardization, February 2014. Accessed November 2026.
- IEC 61672-1:2013 Electroacoustics: Sound level meters, Part 1: Specifications. International Electrotechnical Commission, September 2013. Accessed November 2026.
- Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.