What is a post-installation acoustic test?

A post-installation acoustic test measures a finished room to see whether it meets its acoustic design target. BB93 calls this acoustic commissioning: pre-completion testing and reporting by a specialist acoustic consultant, following the Association of Noise Consultants testing guide for schools. There is no BB93 certificate.[1]

Key points

  • BB93 section 2.3 says pre-completion testing and reporting should be carried out by a specialist acoustic consultant in accordance with the Association of Noise Consultants Good Practice Guide: Acoustic Testing of Schools.[1]
  • The pass criteria are BB93's tables: indoor ambient noise (Table 1), airborne and impact insulation (Tables 3a to 5) and reverberation time (Table 6).[1]
  • Reverberation time is tested to ISO 3382-2 and airborne sound insulation to ISO 16283-1.[2][3]
  • Where a sports hall is designed by calculation and built as designed, commissioning measurement of reverberation time is not required.[4]

How it works

BB93 sets the performance standards and expects them to be shown by evidence. The test compares measured values, for each room type, with the figures in its tables, using the measurement standards: ISO 3382-2 for reverberation time in ordinary rooms and ISO 16283-1 for airborne sound insulation between rooms.[1][2][3]

For airborne insulation, BB93 allows the reference reverberation time to be the measured value in each third octave band during commissioning, provided that Tmf complies with Table 6 and is representative of the room finished and unfurnished.[1]

The numbers

Pass criteria that a school test is compared against, by room type:[1]

  • Indoor ambient noise level, new build classroom: 35 dB LAeq,30mins; refurbishment: 40 dB.[1]
  • Tmf, new build primary classroom: 0.6 s; refurbishment: 0.8 s.[1]
  • DnT,w between two classrooms where the source has average activity noise and the receiving room medium noise tolerance: 45 dB new build, 40 dB refurbishment.[1]
  • Open plan spaces: STI of at least 0.6 within a group and no more than 0.3 between groups, for new build and refurbishment.[1]

In schools and SEN settings

For rooms intended specifically for pupils with special hearing and communication needs the same tests apply against tighter values: 30 dB LAeq,30mins new build (35 dB refurbishment), and a reverberation time of 0.4 s averaged from 125 Hz to 4 kHz with no octave band above 0.6 s, new build.[1] The room has a low noise tolerance, so BB93's sound insulation tables ask for more insulation into it from an average-noise neighbouring room: 50 dB DnT,w new build and 40 dB refurbishment.[1] BB93 frames compliance as design evidence plus pre-completion testing and states no certification scheme; it is guidance that supports Requirement E4 of the Building Regulations and the School Premises Regulations 2012.[1] The design guide advises that notes on subjective impressions be made during testing and that, in some cases, a design appraisal is more suitable than testing.[4]

Worked example

These figures are illustrative. A new build classroom is tested after fit-out. Ambient noise: 34 dB LAeq,30mins, within the 35 dB limit.[1] Reverberation time: Tmf of 0.63 s, above the 0.6 s new build limit, so it fails and remedial absorption is considered.[1] The wall to the next classroom: DnT,w 46 dB, above the 45 dB new build minimum.[1] The report would then list one failure out of three checks.

What people get wrong

  • Calling the result a BB93 certificate. BB93 states no such scheme; compliance is shown by design evidence and pre-completion testing.[1]
  • Using refurbishment values for new work. BB93 says they should not normally be used for new build.[1]
  • Testing in the wrong condition. The reverberation time limits apply to finished rooms, furnished for normal use but unoccupied.[1]

How it is measured

Measurement follows the standards above, using calibrated instruments such as sound level meters specified in IEC 61672-1.[2][3][5] The design guide says testing should follow the Association of Noise Consultants guide and be done by a competent person who records subjective impressions as well.[4]

FAQ

What does BB93 say about testing?

Section 2.3 says pre-completion testing and reporting should be by a specialist acoustic consultant following the Association of Noise Consultants guide.[1]

Is there a BB93 certificate?

No scheme is described in BB93.[1]

What is tested?

Indoor ambient noise, reverberation time and sound insulation, and STI for open plan spaces, against the BB93 tables.[1]

Is testing always required?

The design guide says in some cases it may be unnecessary, for example sports halls designed by calculation and installed as designed.[4]

WorkSpace Acoustics surveys and installs acoustic treatment; contact the team to talk about a room.

Sources

  1. Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.
  2. ISO 3382-2:2008 Acoustics: Measurement of room acoustic parameters, Part 2: Reverberation time in ordinary rooms. International Organization for Standardization, June 2008, confirmed 2022. Accessed November 2026.
  3. ISO 16283-1:2014 Acoustics: Field measurement of sound insulation in buildings and of building elements, Part 1: Airborne sound insulation. International Organization for Standardization, February 2014. Accessed November 2026.
  4. Acoustics of Schools: a design guide. Institute of Acoustics and Association of Noise Consultants, November 2015. Accessed November 2026.
  5. IEC 61672-1:2013 Electroacoustics: Sound level meters, Part 1: Specifications. International Electrotechnical Commission, September 2013. Accessed November 2026.
Expert acoustic consultancy and installation for schools, businesses and restaurants across the UK. Specialists in SEN environments.
A specialist division of: Presentation Spaces Group

COMPANY

About
Why Acoustics
Contact Us
Privacy Policy
Glossary
Acoustics statistics

SECTORS

Schools
Businesses
Restaurants

SERVICES

Acoustic Surveys
Acoustic Design
Installation
© 2026 WorkSpace Acoustics Ltd. All rights reserved.
Product images courtesy of Presentation Spaces Group (used with permission)