What is the speech transmission index (STI)?
The speech transmission index (STI) is an objective measure of speech intelligibility on a scale from 0 to 1, defined in IEC 60268-16. Higher is better. BB93 requires STI of at least 0.6 within a teaching group and no more than 0.3 between groups in open plan school spaces.[1][2][3]
Key points
- STI is a value between 0 and 1, and the higher the value the better the speech intelligibility.[1]
- It accounts for speaker and listener positions, ambient noise, the room's acoustics and speech level.[1]
- BB93 sets STI of at least 0.6 within a teaching group and no more than 0.3 between groups for open plan spaces.[3]
- BB93 requires STI calculations for open plan spaces to comply with the School Premises Regulations.[3]
How it works
The Institute of Acoustics and the Association of Noise Consultants explain that STI is defined in the standard for sound system equipment, and that it accounts for the location of the speaker and listener, ambient noise, the acoustic characteristics of the space and the loudness and quality of speech.[1] To measure it, a special sound source is placed at the speaker's position and the signal is detected at the listening position; signal processing using the modulation transfer function between transmitted and received signals gives the STI.[1]
IEC 60268-16 itself defines the STI model, test signals, measurement and prediction methods. It does not provide STI criteria for certification of transmission channels such as voice-alarm systems, although some typical application values are provided in an annex.[2]
The numbers
The design guide gives these intelligibility ratings, for native listeners with good hearing:[1]
- 0.1 to 0.3: bad.[1]
- 0.3 to 0.45: poor.[1]
- 0.45 to 0.6: fair.[1]
- 0.6 to 0.75: good.[1]
- 0.75 to 1: excellent.[1]
BB93 criteria for open plan spaces, applying to new build and refurbishment alike:[3]
In schools and SEN settings
BB93 applies STI to open plan teaching spaces because noise from activities in adjacent areas raises the background and lowers intelligibility, and it says open plan spaces may be unsuitable for some children, particularly those with special hearing or communication needs.[3] A footnote to its table states that a higher STI may be more appropriate for students with special hearing or communication needs.[3] The design guide gives an enhanced criterion of 0.75 within groups as an example for hearing impaired students, very young children and students with English as an additional language, and warns that it is unlikely to be achievable in all open learning spaces at all seating positions.[1] BB93 strongly recommends STI criteria be written into the employer's requirements and that school clients take independent advice from a suitably qualified acoustic technical adviser, because the design relies on a 3D acoustic model.[3] For moderate and high risk open plan arrangements, it calls STI modelling essential.[3]
Worked example
These figures are illustrative. A prediction gives an STI of 0.52 for a pupil seated within the teaching group. On the design guide's scale that is fair, and it falls short of the BB93 criterion of at least 0.6 for new build and refurbishment.[1][3] A second prediction of 0.35 between groups misses the no more than 0.3 limit by 0.05, so screening or additional absorption would be investigated.[3]
What people get wrong
- Reading STI as a percentage. It is an index from 0 to 1, not a percentage.[1]
- Applying it to every room. BB93 applies STI criteria to open plan spaces, and relies on noise, insulation and reverberation limits in enclosed rooms.[3]
- Treating the BB93 value as the best achievable. The design guide describes 0.6 to 0.75 as good and above 0.75 as excellent.[1]
How it is measured
STI is calculated in accordance with the EN 60268-16 standard, and BB93 says computer modelling is used in design for open plan spaces.[3] IEC 60268-16:2020 is the fifth edition and defines the model, test signals and both measurement and prediction methods.[2]
FAQ
What does STI stand for?
Speech transmission index.[2]
What STI does BB93 require?
For open plan spaces, at least 0.6 within a group and no more than 0.3 between groups.[3]
What is a good STI?
The design guide rates 0.6 to 0.75 as good and above 0.75 as excellent.[1]
Is STI measured or predicted?
Both: the standard covers measurement and prediction methods.[2]
WorkSpace Acoustics surveys and installs acoustic treatment; contact the team to talk about a room.
Sources
- Acoustics of Schools: a design guide. Institute of Acoustics and Association of Noise Consultants, November 2015. Accessed November 2026.
- IEC 60268-16:2020 Sound system equipment, Part 16: Objective rating of speech intelligibility by speech transmission index. International Electrotechnical Commission, September 2020. Accessed November 2026.
- Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.