What is Approved Document B (fire safety)?
Approved Document B is the Government's statutory guidance on fire safety under the Building Regulations 2010 in England. Volume 2 covers buildings other than dwellings, including schools. Its requirement B2 on internal linings, with Table 6.1, sets the minimum reaction-to-fire class for wall and ceiling surfaces: C-s3, d2 for most non-residential rooms.[1][2]
Key points
- GOV.UK lists Approved Document B as statutory guidance for England, first published on 7 December 2010 and last updated on 16 September 2026.[1]
- Volume 1 covers dwellings and Volume 2 covers buildings other than dwellings.[1]
- Requirement B2 says internal linings must adequately resist the spread of flame over their surfaces and have a reasonable rate of heat release or fire growth if ignited.[2]
- The 2025 amendments removed national classes for reaction to fire, so wall and ceiling linings are classified under BS EN 13501-1.[2]
How it works
Part B of Schedule 1 to the Building Regulations 2010 sets the legal requirements, and Approved Document B gives practical guidance on meeting them.[2] Requirement B2 covers internal fire spread over linings, defined as materials or products used in lining any partition, wall, ceiling or other internal structure.[2] The Secretary of State's view is that B2 is met by restricting spread of flame over internal linings, with a limited contribution to fire growth, and linings matter most in circulation spaces.[2] B2 does not give guidance on smoke and fumes generation.[2]
Section 6 of Volume 2 sets the classes for linings in Table 6.1.[2] The classes come from BS EN 13501-1.[2]
The numbers
Table 6.1 of Volume 2 sets the minimum classification for the surface linings of walls and ceilings.[2]
- Small rooms with a maximum internal floor area of 30 m2 in non-residential accommodation: D-s3, d2.[2]
- Other rooms, including garages: C-s3, d2.[2]
- Other circulation spaces: B-s3, d2.[2]
Parts of walls in a room may be of lower performance, but no worse than D-s3, d2, with a total area under half the floor area, up to 60 m2 in non-residential accommodation.[2] Table 6.1 applies to rooms by size and use, so check the rows against the actual building with the building control body.[2]
In schools and SEN settings
BB93 says Requirement B2 controls the contribution that wall and ceiling linings make to the early growth of fire, and that acoustic baffles and products are available with the certification to comply, with certificates of conformity part of the Building Regulations approval process.[3] Free-hanging baffles are not part of the ceiling but should have the appropriate spread of flame classification.[3] BB93's reference list names Approved Document B Volume 2 for buildings other than dwellings.[3]
The sections of Volume 2 read for this page do not treat SEN settings differently from other schools. Anything specific to a special school's fire strategy is a matter for the designer and the building control body.[2]
Worked example
An illustrative primary school corridor is a circulation space, so Table 6.1 asks for B-s3, d2 on its wall and ceiling linings.[2] An illustrative 25 m2 store room is a small non-residential room under 30 m2, so D-s3, d2 is the minimum.[2] The invented rooms show how the minimum depends on the room's size and function.
What people get wrong
How it is checked
Building control approves the design before work starts. BB93 says certificates of conformity form part of that approval process for acoustic linings.[3] The class itself comes from a classification report under BS EN 13501-1.[2]
FAQ
Which volume of Approved Document B applies to schools?
Volume 2, buildings other than dwellings. BB93 refers to Volume 2.[1][3]
Is Approved Document B law?
Part B of Schedule 1 to the Building Regulations is the requirement; the document is statutory guidance on meeting it.[1][2]
Does it apply in Scotland, Wales or Northern Ireland?
GOV.UK says it applies to England, so this page covers England only.[1]
WorkSpace Acoustics surveys and installs acoustic treatment for schools; contact the team to discuss a room.
Sources
- Fire safety: Approved Document B. GOV.UK (Ministry of Housing, Communities and Local Government), last updated 16 September 2026. Accessed November 2026.
- Fire safety: Approved Document B, Volume 2: Buildings other than dwellings. Ministry of Housing, Communities and Local Government, 2019 edition incorporating amendments to 2026. Accessed November 2026.
- Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.
- The changing status of the BS 476 standard series: A summary. BSI, 19 February 2025. Accessed November 2026.