What is BS EN 13501-1?

BS EN 13501-1 is the British adoption of the European standard that sets the procedure for classifying the reaction to fire of construction products, from class A1 down to F, with extra classes for smoke and flaming droplets. The current edition is BS EN 13501-1:2018, published by BSI on 31 January 2019.[1][2]

Key points

  • BS EN 13501-1:2018 is identical to EN 13501-1:2018 and supersedes EN 13501-1:2007+A1:2009, which is withdrawn.[1]
  • It covers three categories separately: construction products excluding floorings and linear pipe thermal insulation, floorings, and linear pipe thermal insulation products.[1]
  • Power, control and communication cables are not covered; EN 13501-6 deals with them.[1]
  • Products are classified in relation to their end-use application, so a class applies only to the product as tested and used.[1][2]

How it works

The standard defines a harmonised procedure for classifying reaction to fire, meaning how a product contributes by its own decomposition to a fire under specified conditions.[1][2] Approved Document B explains the result: products other than floorings are classified A1, A2, B, C, D, E or F, with A1 the highest performance and F the lowest, and F assigned when a product fails to reach E.[2] Untested products cannot be classified under the standard.[2]

Classes A2, B, C, D and E carry additional classifications for smoke production, s1 to s3 with s1 the lowest, and for flaming droplets or particles, d0 to d2 with d0 the lowest.[2] Where a classification includes s3, d2, no limit is set for smoke or droplets.[2]

The numbers

BS EN 13501-1 is a paid standard, and this page does not reproduce its criteria or tables. The facts below come from the BSI catalogue page and from Approved Document B.[1][2]

  • Seven main classes: A1, A2, B, C, D, E and F.[2]
  • Smoke classes s1, s2 and s3; droplet classes d0, d1 and d2.[2]
  • Edition: 2018, published 31 January 2019, replacing the 2007 edition with its 2009 amendment.[1]

In schools and SEN settings

BB93 says Requirement B2 of the Building Regulations controls the contribution that the surface linings of walls and ceilings make to fire growth, and that free-hanging acoustic baffles are not part of the ceiling but should have the appropriate spread of flame classification.[3] Certificates of conformity are part of the Building Regulations approval process.[3] Which class a given school room needs is in Approved Document B, not in BS EN 13501-1.[2]

Approved Document B Table 6.1 sets, for non-residential accommodation, class D-s3, d2 for small rooms up to 30 m2, class C-s3, d2 for other rooms, and class B-s3, d2 for other circulation spaces.[2]

Worked example

An illustrative ceiling product is classified B-s1, d0 under the standard. Against Table 6.1 that is better than the C-s3, d2 required for an ordinary non-residential room, because B ranks above C and s1 and d0 are the lowest smoke and droplet classes.[2] This does not say the product is suitable for a given project; the classification applies only to the product as tested and used.[2]

What people get wrong

  • Quoting a class without the test evidence. Untested products cannot be classified under the standard.[2]
  • Applying a class to a different substrate. The classification is valid only within the direct field of application, for example when fixed to a substrate of the tested type.[2]
  • Using BS 476 results as current. BSI says BS 476-7 is superseded by BS EN 13823 and was removed from Approved Document B on 2 March 2025.[4]

How it is checked

A manufacturer's classification report is issued from test data under the standard, and the end-use field of application, including the substrate, is part of the result.[2] Check the classification report itself, and ask the building control body what it needs for the project.[3] This page states no class for any product.

FAQ

Is BS EN 13501-1 the same as Euroclass?

Euroclass is the system of classes; BS EN 13501-1 is the standard that sets the procedure for deriving them.[1][2]

Is BS 476 still used for reaction to fire?

BSI says the reaction to fire parts of BS 476 were removed from Approved Document B on 2 March 2025.[4]

Does the standard apply in Scotland, Wales or Northern Ireland?

This page covers England; Approved Document B is guidance for England.[2] Check the relevant building standards elsewhere.

WorkSpace Acoustics surveys and installs acoustic treatment for schools; see the products or contact the team.

Sources

  1. BS EN 13501-1:2018 Fire classification of construction products and building elements: Classification using data from reaction to fire tests. BSI, 31 January 2019. Accessed November 2026.
  2. Fire safety: Approved Document B, Volume 2: Buildings other than dwellings. Ministry of Housing, Communities and Local Government, 2019 edition incorporating amendments to 2026. Accessed November 2026.
  3. Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.
  4. The changing status of the BS 476 standard series: A summary. BSI, 19 February 2025. Accessed November 2026.
Expert acoustic consultancy and installation for schools, businesses and restaurants across the UK. Specialists in SEN environments.
A specialist division of: Presentation Spaces Group

COMPANY

About
Why Acoustics
Contact Us
Privacy Policy
Glossary
Acoustics statistics

SECTORS

Schools
Businesses
Restaurants

SERVICES

Acoustic Surveys
Acoustic Design
Installation
© 2026 WorkSpace Acoustics Ltd. All rights reserved.
Product images courtesy of Presentation Spaces Group (used with permission)