What is a sound absorption class?

A sound absorption class is a letter from A to E that groups sound absorbers by their weighted sound absorption coefficient, alpha-w, with Class A the most absorbent. The classification sits in an informative annex of ISO 11654 and is the rating UK school acoustic guidance uses when it specifies absorbers.[1][2]

Key points

  • The class is derived from alpha-w, which is a single number calculated from laboratory absorption coefficients.[1]
  • ISO 11654 gives the classification for information in an annex; the rating itself is alpha-w.[1]
  • A very reflective surface may be unclassified, so not every product has a class.[2]
  • A class is a rough guide. ISO 11654 says complete absorption data by frequency are needed for carefully designed spaces.[1]

How it works

A manufacturer has a sample tested for its sound absorption coefficient in a reverberation room.[3] ISO 11654 then turns the coefficients into one number: the one-third-octave values are converted into octave bands, and a reference curve is shifted in steps of 0.05 towards the measured values until the unfavourable deviations add up to no more than 0.10. Alpha-w is the shifted curve's value at 500 Hz.[1] The class letter is assigned from that single number using the classification in the standard's annex.[1]

This page does not reproduce the limits between classes. The standard is paywalled and the annex was not available to check, so use the current edition of ISO 11654 for them.

The numbers

Alpha-w is quoted to two decimal places, followed by any shape indicators in brackets, for example alpha-w = 0.70(MH).[1] A shape indicator is added when the practical absorption coefficient exceeds the shifted reference curve by 0.25 or more: L for 250 Hz, M for 500 Hz or 1 kHz, and H for 2 kHz or 4 kHz.[1] The design guide describes Class A coverage of 100% of the ceiling area as the recommended absorption area for open plan teaching spaces.[2]

In schools and SEN settings

The Institute of Acoustics design guide refers to absorber classes A to D "as defined in BS EN ISO 11654" when it sets out its sports hall calculations, and it uses the classes when describing absorption in open plan spaces.[2] Its authors say specialist advice from an educational audiologist and a specialist acoustician should always be sought for accommodation designed for hearing impaired pupils.[2] A class letter on a datasheet is therefore an input to that advice, not a substitute for it.

Worked example

In the standard's own example, an unfavourable deviation occurs at 250 Hz and the result is alpha-w = 0.60, with no shape indicator needed.[1] In a second example the absorber exceeds the shifted curve by more than 0.25 at 500 Hz, so the mid-frequency indicator M is added and the result is written alpha-w = 0.60(M).[1] The standard adds that whenever a shape indicator is given, the complete curve should be requested as well.[1]

What people get wrong

  • Assuming Class A suits every job. ISO 11654 says the rating is not appropriate for qualified environments requiring careful acoustical design, where the full curve is needed.[1]
  • Quoting a class for a single item without checking the report. The standard says the rating is often not suitable for single items such as chairs and baffles.[1]
  • Reading a class below 250 Hz. The rating curve has a lower limit of the 250 Hz octave band.[1]

How it is measured

The coefficients behind a class are measured in a reverberation room under ISO 354, which covers wall and ceiling treatments and the absorption area of objects.[3] ISO 11654 applies in principle to all building products measured that way.[1]

FAQ

What do the letters A to E mean?

They group absorbers by alpha-w, with Class A the most absorbent. The class limits are in the informative annex of ISO 11654.[1]

Which class do schools need?

The design guide recommends Class A coverage of 100% of the ceiling area for open plan teaching spaces.[2]

Does a class tell me how well it works in my room?

Not by itself. The result depends on the room, the mounting and the frequency range, which is why the full curve is needed.[1]

WorkSpace Acoustics surveys and installs acoustic treatment; see the products or contact the team.

Sources

  1. ISO 11654:1997 Acoustics: Sound absorbers for use in buildings, Rating of sound absorption. International Organization for Standardization, April 1997, confirmed 2023. Accessed November 2026.
  2. Acoustics of Schools: a design guide. Institute of Acoustics and Association of Noise Consultants, November 2015. Accessed November 2026.
  3. ISO 354:2003 Acoustics: Measurement of sound absorption in a reverberation room. International Organization for Standardization, May 2003, confirmed 2024. Accessed November 2026.
Expert acoustic consultancy and installation for schools, businesses and restaurants across the UK. Specialists in SEN environments.
A specialist division of: Presentation Spaces Group

COMPANY

About
Why Acoustics
Contact Us
Privacy Policy
Glossary
Acoustics statistics

SECTORS

Schools
Businesses
Restaurants

SERVICES

Acoustic Surveys
Acoustic Design
Installation
© 2026 WorkSpace Acoustics Ltd. All rights reserved.
Product images courtesy of Presentation Spaces Group (used with permission)