What is a sound absorption coefficient?

The sound absorption coefficient, written alpha (α), is the share of the sound energy reaching a surface that the surface absorbs. It takes values from 0, a totally reflective surface, to 1, a surface that absorbs everything. It varies with frequency, so it is reported for each octave band.[1]

Key points

  • The coefficient takes values in the range 0 to 1, and most surfaces have values between 0 and 1.[1]
  • Coefficients are generally given for each octave band because absorption varies with frequency.[1]
  • ISO 354 specifies how to measure the coefficient of wall or ceiling treatments in a reverberation room.[2]
  • Single-number ratings such as class A to E under BS EN ISO 11654 are derived from the coefficients across the frequency range.[1]

How it works

The coefficient describes one surface at one frequency. Multiplying it by the surface area gives that surface's absorption in square metres. Adding the products for every surface gives the total absorption ΣSα, which sits in the denominator of the reverberation time equation T = 0.161 V / ΣSα seconds.[1] A higher coefficient means more sound absorbed and a shorter reverberation time.[1]

Coefficients from a laboratory test are not the whole story in a real room. The guide notes that scattering of reflected sound, and the diffusive properties of finishes and contents, influence how effective absorption is in situ.[1]

The numbers

  • Totally reflective surface: α = 0.[1]
  • Surface that absorbs all sound incident on it: α = 1.[1]
  • Reverberation time: T = 0.161 V / ΣSα seconds, with V in cubic metres and S in square metres.[1]
  • Octave bands typically used in building acoustics: 63 Hz to 4 kHz.[1]

In schools and SEN settings

BB93 limits the reverberation time, not the coefficient, so the coefficient is a design input used to show that a ceiling and wall treatment can deliver the limit: 0.6 s for a new build primary classroom, 0.8 s for refurbishment, and 0.4 s averaged from 125 Hz to 4 kHz for a new build teaching space intended specifically for students with special hearing and communication needs.[3] Because BB93 includes the 125 Hz band for those new build rooms, the coefficient at low frequencies matters there, and a product that is strongly absorbent only at high frequencies may not deliver it.[3][1] The design guide notes that suspended absorbers can be effective at mid to high frequencies, while good low frequency absorption is not always achieved and speech covers 125 Hz to 8 kHz.[1]

Worked example

These figures are illustrative, not product data. A 56 m2 ceiling with a coefficient of 0.05 provides 56 x 0.05 = 2.8 m2 of absorption.[1] Replacing it with a finish of coefficient 0.85 gives 56 x 0.85 = 47.6 m2, an increase of 44.8 m2.[1] In a 168 m3 room the reverberation time changes from 0.161 x 168 / 2.8 = 9.7 s to 0.161 x 168 / 47.6 = 0.57 s, ignoring the other surfaces.[1] The first value shows why a bare hard room is so long to decay, and why real rooms have other absorbing surfaces that the simple example leaves out.

What people get wrong

  • Reading one number as a product rating. A coefficient belongs to one octave band; the single-number ratings summarise the set.[1]
  • Mixing up coefficient and class. The class (A to E) is a rating derived from coefficients, not a coefficient itself.[1]
  • Expecting laboratory values in the room. Placement, distribution and scattering change the effect in situ.[1]

How it is measured

ISO 354 specifies measurement of the coefficient for materials used as wall or ceiling treatments in a reverberation room, and the equivalent sound absorption area for objects such as furniture, people or space absorbers.[2] The standard was last reviewed and confirmed in 2024.[2]

FAQ

What range does the absorption coefficient have?

From 0 to 1.[1]

Why is the coefficient given per frequency band?

Because the absorption of a surface varies with frequency.[1]

Which standard measures it?

ISO 354 for the laboratory reverberation room method.[2]

How does it relate to reverberation time?

Total absorption, the sum of area times coefficient, is inversely related to reverberation time in the Sabine-type equation.[1]

WorkSpace Acoustics surveys and installs acoustic treatment; contact the team to talk about a room.

Sources

  1. Acoustics of Schools: a design guide. Institute of Acoustics and Association of Noise Consultants, November 2015. Accessed November 2026.
  2. ISO 354:2003 Acoustics: Measurement of sound absorption in a reverberation room. International Organization for Standardization, May 2003, confirmed 2024. Accessed November 2026.
  3. Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.
Expert acoustic consultancy and installation for schools, businesses and restaurants across the UK. Specialists in SEN environments.
A specialist division of: Presentation Spaces Group

COMPANY

About
Why Acoustics
Contact Us
Privacy Policy
Glossary
Acoustics statistics

SECTORS

Schools
Businesses
Restaurants

SERVICES

Acoustic Surveys
Acoustic Design
Installation
© 2026 WorkSpace Acoustics Ltd. All rights reserved.