What is BB93?
Building Bulletin 93 (BB93) is the Department for Education's guidance on acoustic performance standards for school buildings in England. It sets limits for indoor ambient noise, sound insulation and reverberation time, and describes the normal way to show compliance with Building Regulations Part E and the School Premises Regulations 2012.[1]
Key points
- BB93 is guidance, not legislation. The legal duties sit in the Building Regulations and the School Premises Regulations; meeting BB93 is the normal way to satisfy them.[1]
- Every limit depends on the room type and on whether the work is new build or refurbishment.[1]
- Rooms for pupils with special hearing or communication needs have tighter limits than ordinary classrooms.[1]
- The GOV.UK page for the 2015 edition was last updated on 19 December 2014, and the document gave a review date of 2019, so check GOV.UK for the current version before quoting it.[1][2]
How it works
BB93 is the performance standard for school acoustics. Its section 1 sets limits for indoor ambient noise, airborne and impact sound insulation, and reverberation time. Requirement E4 of the Building Regulations says each room in a school must have acoustic conditions appropriate to its use, and the guidance supporting that requirement points designers to the BB93 values.[1]
The Building Regulations apply to new build and to a material change of use, but not to all refurbishment. The School Premises Regulations apply to new and existing schools, though not retrospectively. BB93 says refurbished elements should meet its guidance as far as reasonably practicable.[1]
The numbers
The upper limits for indoor ambient noise, measured as LAeq,30min in unoccupied rooms, include these.[1]
- Primary or secondary classroom: 35 dB new build, 40 dB refurbishment.[1]
- Open plan teaching area: 40 dB new build, 45 dB refurbishment.[1]
- Teaching space specifically for pupils with special hearing and communication needs: 30 dB new build, 35 dB refurbishment.[1]
- SEN calming room: 35 dB for both new build and refurbishment.[1]
Maximum mid-frequency reverberation time (Tmf) differs again.[1]
- Primary classroom, class base or SEN calming room: 0.6 s new build, 0.8 s refurbishment.[1]
- Secondary classroom or general teaching area: 0.8 s new build, 1.0 s refurbishment.[1]
- Teaching space specifically for pupils with special hearing and communication needs: an average of 0.4 s from 125 Hz to 4 kHz and no more than 0.6 s in any octave band for new build, and 0.4 s for refurbishment.[1]
Sound insulation between rooms is set as DnT,w. Two ordinary classrooms side by side need at least 45 dB new build or 40 dB refurbishment.[1] Open plan teaching spaces also carry a speech transmission index target of at least 0.6 within a teaching group and no more than 0.3 between groups.[1]
In schools and SEN settings
BB93 says pupils with special educational needs are generally more sensitive to the acoustic environment, so required reverberation times are shorter, insulation higher and ambient noise lower for their rooms.[1] It lists pupils who may have special hearing or communication needs, including those with permanent or fluctuating hearing impairment, speech, language and communication difficulties, ADHD, auditory processing disorder or autism.[1]
The figures for these rooms are described as a starting point. Alternative performance standards are commonly needed, and the design of special school accommodation should involve an acoustician and, for pupils with hearing impairment, an audiologist.[1]
What people get wrong
- Treating it as the law. BB93 supports compliance with the regulations; it is not itself a statute.[1]
- Quoting one figure for every classroom. The 0.4 s limit applies to rooms intended specifically for pupils with special hearing or communication needs.[1] A primary classroom is 0.6 s for new build.[1]
- Using refurbishment values for new build. BB93 says refurbishment figures should not normally be used for new build unless there are over-riding educational, environmental or health and safety reasons.[1]
How it is checked
BB93 section 2 says pre-completion testing and reporting should be carried out by a specialist acoustic consultant, following the Association of Noise Consultants guide to acoustic testing of schools. It strongly recommends the client requires testing in the building contract.[1] The Institute of Acoustics and Association of Noise Consultants design guide supports the standard with design advice.[3]
FAQ
Is BB93 mandatory?
BB93 is guidance. The mandatory parts are Requirement E4 of the Building Regulations and the School Premises Regulations, and BB93 describes the normal means of meeting them.[1]
Does BB93 apply to refurbishment?
Yes, through refurbishment values. The School Premises Regulations apply to refurbishment work, and BB93 gives separate, less demanding figures for refurbished elements.[1]
What is the BB93 limit for a primary classroom?
For new build, 35 dB LAeq,30min ambient noise and a Tmf of no more than 0.6 s.[1] For refurbishment, 40 dB and 0.8 s.[1]
WorkSpace Acoustics surveys and installs acoustic treatment for schools; contact the team to discuss a room.
Sources
- Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.
- Acoustic design of schools: performance standards: BB 93. GOV.UK (Department for Education), last updated 19 December 2014. Accessed November 2026.
- Acoustics of Schools: a design guide. Institute of Acoustics and Association of Noise Consultants, November 2015. Accessed November 2026.