What is the Noise Reduction Coefficient (NRC)?

Noise Reduction Coefficient (NRC) is a single-number rating of how much sound a material absorbs, calculated from absorption coefficients measured in a reverberation room.[1] UK school guidance does not use NRC; it rates absorbers by class A to E under ISO 11654, based on the weighted coefficient alpha-w.[2][3]

Key points

  • NRC is one number summarising a material's absorption. The coefficients behind it come from a reverberation-room test.[1]
  • UK school design guidance refers to absorption classes A to E rated under ISO 11654, not to NRC.[2]
  • NRC and alpha-w are different single-number ratings from different standards, so a value in one cannot be swapped for a value in the other.[3]
  • Single-number ratings hide detail. ISO 11654 says complete absorption data by frequency are needed for carefully designed spaces.[3]

How it works

Every absorption rating starts with a laboratory test. A sample is placed in a reverberation room and the decay rate of sound is measured with and without it; ASTM C423 is the United States test method for this, and ISO 354 is the international one.[1][4] The test gives an absorption coefficient for each frequency band. A single-number rating then condenses those values into one figure to make products easy to compare.

The averaging rule is set in the ASTM standards, which are paywalled and not reproduced here. A reader who needs the exact method should read the current edition, and a datasheet should state which standard and edition its figure came from.[1]

The numbers

The numbers that matter for a UK school specification come from ISO 11654, not NRC. That standard converts one-third-octave coefficients measured under ISO 354 into octave bands, shifts a reference curve in steps of 0.05 until the unfavourable deviations total no more than 0.10, and reads alpha-w as the curve's value at 500 Hz.[3]

ASTM C423 itself notes that coefficients can exceed 1 for highly absorptive specimens because of diffraction effects, and that they should be used with caution because in practice the sound field is rarely diffuse.[1]

In schools and SEN settings

The Institute of Acoustics design guide cites ISO 11654 classes when it sets out absorption for school spaces. For open plan teaching spaces it recommends an absorption area equivalent to Class A coverage of 100% of the ceiling area, and it uses Class A to D absorbers when describing sports hall calculations.[2] A school specification for a room for pupils with special hearing needs should therefore ask for an ISO 354 test report giving alpha-w and class, plus the full coefficient curve.

A product sold with only an NRC figure leaves a UK designer without the class or alpha-w that the guidance uses.

Worked example

Two datasheets list a ceiling baffle. One gives "NRC 0.85". The other gives an ISO 354 test, an alpha-w value and a class letter. Only the second can be checked against the class language in UK school guidance. The first needs a further request for the test report, because the NRC value does not reveal the class.[2][3]

What people get wrong

  • Reading NRC as an alpha-w. They come from different standards and are calculated differently.[3]
  • Treating a high single number as proof of fit. ISO 11654 says the rating is not appropriate for carefully designed environments and is not suitable for single items such as chairs and baffles.[3]
  • Forgetting low frequencies. The ISO 11654 rating curve has a lower limit of the 250 Hz octave band, so the rating says nothing below that.[3]

How it is measured

Absorption coefficients are measured in a reverberation room, following ASTM C423 in the United States or ISO 354 internationally.[1][4] ISO 354 covers wall or ceiling treatments and the absorption area of objects such as furniture, persons or space absorbers.[4]

FAQ

Is NRC used in UK schools?

UK school design guidance refers to absorber classes under ISO 11654 rather than NRC.[2]

What is the UK equivalent of NRC?

The nearest UK and European equivalent is the weighted sound absorption coefficient alpha-w with its class letter, both set by ISO 11654.[3]

Can NRC be above 1?

The underlying ASTM C423 coefficients can exceed 1 for highly absorptive specimens because of diffraction effects.[1]

WorkSpace Acoustics surveys and installs acoustic treatment; contact the team to discuss absorber specifications.

Sources

  1. ASTM C423-23 Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method. ASTM International, 2023. Accessed November 2026.
  2. Acoustics of Schools: a design guide. Institute of Acoustics and Association of Noise Consultants, November 2015. Accessed November 2026.
  3. ISO 11654:1997 Acoustics: Sound absorbers for use in buildings, Rating of sound absorption. International Organization for Standardization, April 1997, confirmed 2023. Accessed November 2026.
  4. ISO 354:2003 Acoustics: Measurement of sound absorption in a reverberation room. International Organization for Standardization, May 2003, confirmed 2024. Accessed November 2026.
Expert acoustic consultancy and installation for schools, businesses and restaurants across the UK. Specialists in SEN environments.
A specialist division of: Presentation Spaces Group

COMPANY

About
Why Acoustics
Contact Us
Privacy Policy
Glossary
Acoustics statistics

SECTORS

Schools
Businesses
Restaurants

SERVICES

Acoustic Surveys
Acoustic Design
Installation
© 2026 WorkSpace Acoustics Ltd. All rights reserved.
Product images courtesy of Presentation Spaces Group (used with permission)