What are the acoustic requirements for a school dining hall?

School dining hall acoustics are the noise and reverberation conditions in a room used for school meals. BB93 lists a dining room at an indoor ambient noise limit of 45 dB LAeq,30min and a mid-frequency reverberation time of 1.0 s or less for new build, and 50 dB and 1.5 s for refurbishment.[1]

Key points

  • BB93 allows a higher ambient noise level in a dining room than in a classroom, because BB93 classes it as high activity noise and high noise tolerance.[1]
  • The new build reverberation limit is 1.0 s, against 0.6 s for a primary classroom.[1]
  • BB93 says serving hatches between kitchens and multi-purpose halls used for dining should be avoided where practicable.[1]
  • The Institute of Acoustics design guide says dining areas can suffer from high activity noise that interferes with conversation and leads to rising noise levels.[2]

How it works

In a hard-surfaced dining room each voice adds to the reverberant noise, and the design guide says people in reverberant rooms tend to raise their voices to be heard, which makes the noise worse. It describes this as a common feature of school dining rooms and sports halls, and names it the Lombard effect.[2] Sound absorption is therefore needed to reduce the reverberant noise, and the design guide says the most practical places for it are the ceiling and the walls.[2]

The design guide also advises avoiding shapes in section or plan that produce focusing, such as barrel vaulted roofs and circular walls, unless they are treated with sound absorbent material.[2]

The numbers

BB93 gives these values for finished, furnished and unoccupied rooms.[1]

  • Dining room, indoor ambient noise: 45 dB LAeq,30min new build, 50 dB refurbishment.[1]
  • Dining room, reverberation time Tmf: 1.0 s or less new build, 1.5 s or less refurbishment.[1]
  • Kitchen: 50 dB LAeq,30min new build, 55 dB refurbishment; reverberation 1.5 s or less new build, 2.0 s or less refurbishment.[1]
  • Airborne sound insulation from a dining room (high activity noise) to a classroom (medium noise tolerance): at least 50 dB DnT,w new build, 45 dB refurbishment.[1]
  • Where a serving hatch cannot be avoided, it should have as high a level of sound insulation as practicable, not less than 18 dB Rw.[1]

In schools and SEN settings

The design guide says dining areas are among the communal spaces where important social interaction takes place, and that they need to be designed with the acoustic needs of hearing impaired pupils and pupils with special listening difficulties in mind.[2] BB93 says pupils with special educational needs are generally more sensitive to the acoustic environment than others, and that pupils with autism and other special needs are often very sensitive to specific types of noise, particularly tonal, impulsive or intermittent noise.[1] BB93 also says that where a room is used for more than one purpose, the most onerous condition should be used.[1]

Worked example

These figures are illustrative, not a measured hall. A dining hall of 12 m by 10 m with a 3.5 m ceiling has a volume of 420 m³.[2] The Sabine relation quoted in the design guide gives total absorption for 1.0 s of 0.161 × 420 ÷ 1.0 = 67.6 m², and for the 1.5 s refurbishment limit 0.161 × 420 ÷ 1.5 = 45.1 m².[2] BB93 limits apply to the unoccupied room.[1]

What people get wrong

  • Using the classroom figures. A dining room is 1.0 s for new build, not 0.6 s.[1]
  • Forgetting the kitchen. BB93 recommends servery placement and hatch insulation to limit noise transfer during meal preparation, and says exams should not be timetabled in a hall used for dining while the kitchen is in use.[1]
  • Quoting an old edition. The GOV.UK page for BB93 was last updated on 19 December 2014, so check it for a newer edition before quoting figures.[3]

How it is measured or checked

BB93 section 2.3 says pre-completion testing and reporting should be carried out by a specialist acoustic consultant, following the Association of Noise Consultants good practice guide to acoustic testing of schools.[1]

FAQ

What is the BB93 reverberation time for a school dining room?

It is 1.0 s or less for new build and 1.5 s or less for refurbishment.[1]

How loud can a school dining room be?

BB93 sets an upper limit for indoor ambient noise of 45 dB LAeq,30min for new build and 50 dB for refurbishment, measured in the unoccupied room.[1]

Why are dining halls so noisy?

The design guide says hard surfaces, long reverberation and the Lombard effect make speakers raise their voices, which raises the noise level.[2]

WorkSpace Acoustics surveys and installs acoustic treatment for schools; contact the team to discuss a room.

Sources

  1. Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.
  2. Acoustics of Schools: a design guide. Institute of Acoustics and Association of Noise Consultants, November 2015. Accessed November 2026.
  3. Acoustic design of schools: performance standards: BB 93. GOV.UK (Department for Education), last updated 19 December 2014. Accessed November 2026.
Expert acoustic consultancy and installation for schools, businesses and restaurants across the UK. Specialists in SEN environments.
A specialist division of: Presentation Spaces Group

COMPANY

About
Why Acoustics
Contact Us
Privacy Policy
Glossary
Acoustics statistics

SECTORS

Schools
Businesses
Restaurants

SERVICES

Acoustic Surveys
Acoustic Design
Installation
© 2026 WorkSpace Acoustics Ltd. All rights reserved.
Product images courtesy of Presentation Spaces Group (used with permission)