What is frequency in acoustics?
Frequency is the number of vibration cycles per second of a sound, measured in hertz (Hz), and it corresponds to musical pitch. The human ear responds to frequencies from about 20 Hz to 20 kHz.[1] Standards report results in octave bands, for example BB93 averages the 500 Hz, 1 kHz and 2 kHz bands for new build and refurbishment alike.[2]
Key points
- Frequency is analogous to musical pitch and is measured in cycles per second, or hertz (Hz).[1]
- The human ear is sensitive to sound in the range 20 Hz to 20 kHz.[1]
- For an octave band the upper limiting frequency is twice the lower limiting frequency.[1]
- Absorption, reverberation time and sound insulation all vary with frequency, so they are reported per band.[1]
How it works
A sound source such as a voice or a loudspeaker makes the air vibrate, and the rate of vibration is the frequency. The Institute of Acoustics and the Association of Noise Consultants note that frequency depends on the rate of vibration of the air molecules that carry the sound.[1] Low frequencies are heard as deep, bass sounds and high frequencies as treble sounds.
For acoustic engineering, the frequency range is divided into bands. Octave bands are described by their centre frequencies, and the bands typically used in building acoustics run from 63 Hz to 4 kHz.[1] Each octave can be divided into three one-third octave bands, and those typically used in building acoustics run from 50 Hz to 5 kHz.[1]
The numbers
- Range of human hearing: 20 Hz to 20 kHz.[1]
- Octave bands in building acoustics: 63 Hz, 125 Hz, 250 Hz, 500 Hz, 1 kHz, 2 kHz and 4 kHz.[1]
- BB93 mid-frequency reverberation time (Tmf), new build and refurbishment: the average of the 500 Hz, 1 kHz and 2 kHz octave bands, or of the nine one-third octave bands from 400 Hz to 2.5 kHz.[1][2]
- A-weighting correction: minus 16.1 dB at 125 Hz, 0 dB at 1 kHz and plus 1.2 dB at 2 kHz.[1]
In schools and SEN settings
BB93 ties its reverberation time limit to frequency. For a teaching space intended specifically for students with special hearing and communication needs, the limit is a reverberation time of 0.4 s or less averaged over the 125 Hz to 4 kHz octave bands, with no octave band in that range above 0.6 s, for new build; the refurbishment figure is 0.4 s.[2] That is a wider range of frequencies than the 500 Hz to 2 kHz average used for ordinary classrooms, so low-frequency decay counts in these rooms.[2] The weighted sound insulation values BB93 uses are rated from 100 Hz to 3.15 kHz one-third octave bands, in new build and refurbishment alike.[1]
Worked example
These figures are illustrative. A reverberation time is measured as 0.9 s at 500 Hz, 0.7 s at 1 kHz and 0.5 s at 2 kHz.[1] The mid-frequency value is (0.9 + 0.7 + 0.5) / 3 = 0.70 s.[1] That is above the 0.6 s new build limit for a primary classroom and below the 0.8 s refurbishment limit.[2] Quoting the band values as well shows where the excess sits: at 500 Hz.[1]
What people get wrong
- Treating pitch and loudness as the same thing. Frequency is pitch; level in decibels is a separate quantity.[1]
- Using one number for every frequency. The absorption of surfaces varies with frequency, which is why coefficients are given for each octave band.[1]
- Assuming the ear hears all frequencies equally. Its sensitivity depends on frequency, which is why A-weighting exists.[1]
How it is measured
Frequency analysis uses octave or one-third octave band filters on the measured signal. Reverberation time measurements to ISO 3382-2 are made per band, and the standard describes the measurement procedure, apparatus and evaluation of the data.[3] Absorption coefficients from the reverberation room method of ISO 354 are likewise reported per band.[4]
FAQ
What is the frequency range of human hearing?
About 20 Hz to 20 kHz.[1]
What is the difference between an octave band and a one-third octave band?
An octave band spans a doubling of frequency, and each octave band can be divided into three one-third octave bands.[1]
Which frequencies does BB93 use for reverberation time?
The 500 Hz, 1 kHz and 2 kHz octave bands, or the one-third octave bands from 400 Hz to 2.5 kHz, in both new build and refurbishment.[1][2]
Why do rooms for deaf pupils use a wider frequency range?
For new build rooms intended specifically for students with special hearing and communication needs, BB93 asks for 0.4 s averaged from 125 Hz to 4 kHz.[2]
WorkSpace Acoustics surveys and installs acoustic treatment; contact the team to talk about a room.
Sources
- Acoustics of Schools: a design guide. Institute of Acoustics and Association of Noise Consultants, November 2015. Accessed November 2026.
- Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.
- ISO 3382-2:2008 Acoustics: Measurement of room acoustic parameters, Part 2: Reverberation time in ordinary rooms. International Organization for Standardization, June 2008, confirmed 2022. Accessed November 2026.
- ISO 354:2003 Acoustics: Measurement of sound absorption in a reverberation room. International Organization for Standardization, May 2003, confirmed 2024. Accessed November 2026.