What is BS EN ISO 354?

ISO 354:2003, adopted in the UK as BS EN ISO 354, specifies how to measure the sound absorption coefficient of wall and ceiling treatments, or the equivalent absorption area of objects, in a reverberation room. It is the laboratory test behind the absorption figures that manufacturers publish, and it is a paid standard.[1]

Key points

  • ISO 354:2003 is Edition 2, published in May 2003 and last reviewed and confirmed in 2024, so it remains current.[1]
  • It measures the absorption coefficient of materials used as wall or ceiling treatments, and the equivalent absorption area of objects such as furniture, people or space absorbers.[1]
  • It is not intended for measuring the absorption of weakly damped resonators.[1]
  • Results can be used for comparison and for design calculation in room acoustics and noise control.[1]

How it works

The test takes place in a reverberation room, a laboratory space, not in a finished classroom.[1] The ISO catalogue abstract gives the scope. The procedure, the room requirements and the calculation are in the paywalled text, which this page does not reproduce.[1]

ISO 354 replaced the 1985 edition and its 1997 amendment.[1] In the UK, Approved Document E lists the earlier BS EN 20354:1993 as withdrawn and superseded by BS EN ISO 354:2003.[2] When a datasheet cites "ISO 354", check the year, because 2003 is the current edition.[1]

The numbers

ISO 354 produces a coefficient between 0 and 1, which design guidance then uses.[3]

  • A surface that reflects all sound has an absorption coefficient of 0, and one that absorbs all sound that strikes it has a coefficient of 1.[3]
  • Coefficients are generally given for each octave band, because absorption varies with frequency.[3]
  • ISO 11654 then converts these frequency-by-frequency coefficients into a single rating, alpha-w, and an absorption class from A to E.[4][3]

In schools and SEN settings

The Institute of Acoustics and Association of Noise Consultants design guide uses absorption coefficients in its Sabine calculations for classrooms, sports halls and other rooms. It says assumptions should be explained and justified where laboratory test data are not available.[3] Laboratory data of this kind therefore sit at the start of a school acoustic specification, while the limit for the finished room is the BB93 reverberation time.[3]

For rooms intended for pupils with special hearing or communication needs, BB93 averages reverberation time over the 125 Hz to 4 kHz octave bands, so the frequency range of any absorption data matters for those rooms.[3]

Worked example

An illustrative absorber has a coefficient of 0.9 at 1 kHz.[3] Ten square metres of it adds 10 x 0.9 = 9 m2 of equivalent absorption at that frequency, which is the S x alpha term in the Sabine formula T = 0.161 V / the sum of S x alpha.[3] A room that needs 40 m2 of absorption at 1 kHz would need about 44 m2 of this absorber if nothing else absorbed.[3]

What people get wrong

  • Treating a lab coefficient as an installed result. It is measured in a reverberation room. The finished room is a different test, normally ISO 3382-2.[1][3]
  • Reading the class as the test. ISO 354 gives coefficients; the class letter comes from ISO 11654.[4]
  • Quoting an old edition. The 1993 and 1985 versions are superseded.[1][2]

How it is measured

ISO 354 results come from a reverberation room and are reported as coefficients for wall or ceiling treatments, or as equivalent absorption areas for objects.[1] ISO 11654, a 7-page standard also confirmed in 2023, then rates those results.[4] The finished room is checked separately, with reverberation time measured under ISO 3382-2.[3]

FAQ

What does ISO 354 measure?

The sound absorption coefficient of wall or ceiling treatments, or the equivalent absorption area of objects, in a reverberation room.[1]

Is ISO 354 the same as ISO 11654?

No. ISO 354 is the measurement method, and ISO 11654 is the rating method that turns the results into alpha-w and a class.[1][4]

Is ISO 354 free to read?

No. It is published by ISO and sold through its catalogue; this page uses the catalogue abstract.[1]

WorkSpace Acoustics surveys and installs acoustic treatment for schools; see the products or contact the team.

Sources

  1. ISO 354:2003 Acoustics: Measurement of sound absorption in a reverberation room. International Organization for Standardization, May 2003, confirmed 2024. Accessed November 2026.
  2. Approved Document E: resistance to the passage of sound. Ministry of Housing, Communities and Local Government, 2003 edition incorporating 2004, 2010 and 2013 amendments. Accessed November 2026.
  3. Acoustics of Schools: a design guide. Institute of Acoustics and Association of Noise Consultants, November 2015. Accessed November 2026.
  4. ISO 11654:1997 Acoustics: Sound absorbers for use in buildings, Rating of sound absorption. International Organization for Standardization, April 1997, confirmed 2023. Accessed November 2026.
Expert acoustic consultancy and installation for schools, businesses and restaurants across the UK. Specialists in SEN environments.
A specialist division of: Presentation Spaces Group

COMPANY

About