What are the acoustic requirements for an SEN classroom?
BB93 sets tighter acoustic limits for a teaching space intended specifically for pupils with special hearing or communication needs than for an ordinary classroom. For new build these are indoor ambient noise of no more than 30 dB LAeq,30min and a reverberation time averaging 0.4 s or less from 125 Hz to 4 kHz.[1]
Key points
- BB93 has no row called "SEN classroom". Its rows are "teaching space intended specifically for students with special hearing and communication needs" and "SEN calming room".[1]
- The limits for the special hearing and communication needs teaching space are 30 dB new build and 35 dB refurbishment for ambient noise.[1]
- BB93 describes these figures as a starting point, and an acoustician and the school client body should agree the criteria for each room.[1]
- A classroom for these pupils is not a substitute for good conditions elsewhere in the school.[2]
How it works
BB93 says children with special hearing or communication needs may include, but are not limited to, children with permanent hearing impairment, speech, language and communication difficulties, visual impairments, fluctuating hearing impairment from conductive hearing loss, ADHD, auditory processing disorder or autism.[1] It says pupils with hearing impairment, autism and other special needs are often very sensitive to specific types of noise, particularly those with strong tonal, impulsive or intermittent characteristics.[1]
For this reason the room is described by a tighter row of values. Because the 0.4 s criterion is set at low frequencies as well, reverberation is averaged over the 125 Hz to 4 kHz octave bands rather than the 500 Hz to 2 kHz bands used elsewhere.[1]
The numbers
BB93 gives these limits for finished, furnished and unoccupied rooms.[1]
- Teaching space intended specifically for students with special hearing and communication needs, indoor ambient noise: 30 dB LAeq,30min new build, 35 dB refurbishment.[1]
- The same room, reverberation: 0.4 s or less averaged from 125 Hz to 4 kHz and 0.6 s or less in every octave band, new build; 0.4 s or less for refurbishment.[1]
- Airborne sound insulation into this room from a source room with average activity noise: at least 50 dB DnT,w new build, 40 dB refurbishment.[1]
- SEN calming room: 35 dB LAeq,30min for both new build and refurbishment, with a reverberation time of 0.6 s or less new build and 0.8 s or less refurbishment.[1]
- Summertime ventilation noise allowances do not apply to classrooms intended specifically for these pupils.[1]
In schools and SEN settings
BB93 says alternative performance standards are commonly required for these rooms and should be agreed by an acoustician and the school client body.[1] It adds that the design of special school accommodation and of special units attached to mainstream schools should always involve an acoustician and, for pupils with hearing impairment, an audiologist.[1]
The design guide describes a resource provision for deaf pupils as having excellent sound insulation, very short reverberation times, very low ambient noise levels and flexible space for individual and small group work.[2] It says specialised facilities are not a substitute for addressing the listening needs of pupils taught in regular classrooms.[2] A quiet room attached to a classroom needs enough sound insulation for pupils to talk without disturbing, or being disturbed by, the rest of the class.[2] The National Deaf Children's Society says assistive listening technology such as radio aids and soundfield systems should be used as well as, not instead of, good acoustics.[3]
Worked example
These figures are illustrative, not a measured room. A teaching space of 50 m² with a 2.8 m ceiling has a volume of 140 m³.[2] The Sabine relation gives total absorption for 0.4 s of 0.161 × 140 ÷ 0.4 = 56.4 m², compared with 37.6 m² for the 0.6 s a new build primary classroom allows.[2] The design guide cautions that this relation assumes an even sound field.[2]
What people get wrong
- Applying 0.4 s to every SEN pupil's classroom. The 0.4 s limit applies to rooms intended specifically for pupils with special hearing or communication needs, not to every room where such pupils are taught.[1]
- Treating the table as the finished brief. BB93 says the figures are a starting point and may not suit some types of accommodation.[1]
- Assuming the room fixes the individual need. BB93 says the required conditions depend on a pupil's individual needs and may be met by a specialist room, an assisted listening device or better general conditions.[1]
How it is measured or checked
BB93 section 2.3 says pre-completion testing and reporting should be carried out by a specialist acoustic consultant.[1] The acoustic criteria for these rooms should be signed off by the school client body in the same way as alternative performance standards.[1]
FAQ
What is the BB93 reverberation time for an SEN classroom?
For a teaching space intended specifically for pupils with special hearing or communication needs it is 0.4 s or less, averaged from 125 Hz to 4 kHz, and no more than 0.6 s in any octave band, for new build.[1]
What is the ambient noise limit?
It is 30 dB LAeq,30min for new build and 35 dB for refurbishment.[1]
Does BB93 cover sensory rooms?
BB93 lists an SEN calming room at 35 dB LAeq,30min for new build and refurbishment alike.[1] Other room names are matched to the nearest row.[1]
WorkSpace Acoustics surveys and installs acoustic treatment for schools; contact the team to discuss a room.
Sources
- Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.
- Acoustics of Schools: a design guide. Institute of Acoustics and Association of Noise Consultants, November 2015. Accessed November 2026.
- Creating good listening conditions. National Deaf Children's Society, last reviewed May 2025. Accessed November 2026.