What is a sound level meter?

A sound level meter is an instrument that measures sound pressure level in decibels, with frequency weighting such as A-weighting and time averaging. IEC 61672-1 specifies two performance categories, class 1 and class 2, and class 2 acceptance limits are greater than or equal to those of class 1.[1]

Key points

  • IEC 61672-1:2013 covers time-weighting, integrating-averaging and integrating sound level meters.[1]
  • Class 1 and class 2 are the two performance categories, and class 2 limits are wider.[1]
  • Meters are fitted with a weighting network approximating the ear's response, giving a single dB(A) value.[2]
  • Time constants, defined in international standards, include fast (125 ms) and slow (1 s).[2]

How it works

The Institute of Acoustics and the Association of Noise Consultants explain that meters use sound pressure levels averaged over short intervals within the overall measurement period, with the fast and slow time constants, and that LAeq is not affected by the time constant while LAmax and LAmin can be measured with either, so the one used must be stated.[2] By definition all percentile levels such as LA90 must be measured with the fast time constant.[2]

IEC 61672-1 says a meter may be a self-contained hand-held instrument with an attached microphone and display, or separate components in one or more enclosures, and may be built for use with an operator present or for automatic and continuous measurement.[1] Conformance is demonstrated when measured deviations from design goals do not exceed the acceptance limits and the uncertainty of measurement does not exceed the maximum permitted, determined for a coverage probability of 95%.[1]

The numbers

  • Performance categories under IEC 61672-1:2013: class 1 and class 2.[1]
  • Fast time constant: 125 ms; slow time constant: 1 s.[2]
  • Edition: IEC 61672-1:2013, second edition, which cancelled and replaced the 2002 first edition; stability date 2029.[1]
  • A-weighting corrections for octave bands include minus 16.1 dB at 125 Hz and plus 1.2 dB at 2 kHz.[2]

In schools and SEN settings

BB93 states its indoor ambient noise limits as LAeq,30mins, which needs a meter that integrates over a period and applies A-weighting, such as the integrating-averaging type IEC 61672-1 describes.[3][1] The limits are 35 dB new build and 40 dB refurbishment for classrooms, and 30 dB new build and 35 dB refurbishment for teaching spaces for students with special hearing and communication needs, measured in unoccupied rooms with ventilation operating as BB93 specifies.[3] For an external noise survey on a school site the design guide says measurements should be taken during school hours over a suitable period to quantify the representative LAeq,30min, including noisy events such as peak-hour traffic.[2]

Worked example

These figures are illustrative. A 30 minute measurement is 1,800 s.[2] With the fast time constant of 125 ms the meter averages 1,800 / 0.125 = 14,400 short intervals.[2] The meter reports one LAeq,30min value for the whole period, and the same run can report LA90 for the background level.[2]

What people get wrong

  • Quoting a level without settings. The result needs the weighting, time constant and period; LAmax can differ between fast and slow.[2]
  • Assuming any meter is acceptable evidence. The classes in IEC 61672-1 set different acceptance limits, and class 2 limits are wider.[1]

How it is measured

The standard defines what the instrument must do rather than how a room is surveyed. Room measurements follow the relevant standard, for example ISO 3382-2 for reverberation time and ISO 16283-1 for airborne sound insulation between rooms, each of which specifies how room measurements are made.[4][5]

FAQ

What is the difference between class 1 and class 2?

They are two performance categories in IEC 61672-1, and class 2 acceptance limits are greater than or equal to class 1.[1]

What time constants do meters use?

Fast (125 ms) and slow (1 s).[2]

Which settings does BB93 need?

A-weighted LAeq over 30 minutes for indoor ambient noise.[3]

Does the time constant affect LAeq?

No.[2]

WorkSpace Acoustics surveys and installs acoustic treatment; contact the team to talk about a room.

Sources

  1. IEC 61672-1:2013 Electroacoustics: Sound level meters, Part 1: Specifications. International Electrotechnical Commission, September 2013. Accessed November 2026.
  2. Acoustics of Schools: a design guide. Institute of Acoustics and Association of Noise Consultants, November 2015. Accessed November 2026.
  3. Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.
  4. ISO 3382-2:2008 Acoustics: Measurement of room acoustic parameters, Part 2: Reverberation time in ordinary rooms. International Organization for Standardization, June 2008, confirmed 2022. Accessed November 2026.
  5. ISO 16283-1:2014 Acoustics: Field measurement of sound insulation in buildings and of building elements, Part 1: Airborne sound insulation. International Organization for Standardization, February 2014. Accessed November 2026.
Expert acoustic consultancy and installation for schools, businesses and restaurants across the UK. Specialists in SEN environments.
A specialist division of: Presentation Spaces Group

COMPANY

About
Why Acoustics
Contact Us
Privacy Policy
Glossary
Acoustics statistics

SECTORS

Schools
Businesses
Restaurants

SERVICES

Acoustic Surveys
Acoustic Design
Installation
© 2026 WorkSpace Acoustics Ltd. All rights reserved.
Product images courtesy of Presentation Spaces Group (used with permission)