Acoustic treatment for schools and SEN settings

WorkSpace Acoustics surveys, designs and installs acoustic treatment for schools, with a focus on special educational needs (SEN) settings. We measure how each room sounds, recommend treatment and test the room again once it is installed.

Book a site survey

Why acoustics matter in schools

These are the figures and official statements we point headteachers, SENCOs and estates leads to.

  • About one pupil in five in England has identified special educational needs: 20.8% in January 2026, with 6.0% on an EHC plan and 14.8% on SEN support (our calculation, DfE, Jun 2026).
  • The Department for Education's inclusive education estates guidance says feelings of overwhelm among children and young people with SEND can be intensified by sensory overload arising from the design of the building, and names crowds, noise and busy circulation routes as examples (DfE, Jun 2026).
  • BB93 says pupils with special educational needs are generally more sensitive to the acoustic environment, so the required reverberation times are shorter, sound insulation higher and ambient noise lower for their rooms (DfE, BB93, Feb 2015).
  • The National Deaf Children's Society gives 60 to 77 dB as the noise level of an average school classroom, and says evidence shows 6-year-olds need speech at least 15 dB above background noise (NDCS, reviewed May 2025). See listening conditions.
  • NICE's autism guideline for under 19s says to take account of the physical environment, including individual sensitivities to lighting, noise levels and the colour of walls and furnishings (NICE CG170, Aug 2013).
  • In a 2006 experiment in which six Year 3 classes were randomly assigned to noise conditions, children with SEN were differentially and negatively affected in the classroom babble condition (British Educational Research Journal, Jun 2006).

The wider evidence, 152 sourced statistics, is on our classroom acoustics and SEN statistics page.

What BB93 asks for

BB93 (Building Bulletin 93) is Department for Education guidance, not law. The legal duties sit in the Building Regulations (Requirement E4 of Approved Document E) and the School Premises Regulations 2012; meeting BB93 is the normal way to satisfy them (DfE, BB93, Feb 2015).

Table 6 of BB93 sets the maximum mid-frequency reverberation time, Tmf, in seconds, for rooms that are finished and furnished but unoccupied:

Room typeNew build (s)Refurbishment (s)
Nursery room; primary classroom, class base, general teaching area, small group room, SEN calming room0.60.8
Secondary classroom, general teaching area, seminar, tutorial or language room; study room; science laboratory; design and technology rooms; ICT room; art0.81.0
Teaching space intended specifically for students with special hearing or communication needs0.4 averaged over 125 Hz to 4 kHz, and no more than 0.6 in every octave band0.4

The 0.4 second row is for a teaching space intended specifically for pupils with special hearing or communication needs, not for every classroom where a pupil with SEN is taught. BB93 calls these figures a starting point, to be agreed by an acoustician and the school. The full table is on our BB93 reverberation time limits page.

Rooms we treat

Classrooms

Large rooms with hard wall and ceiling surfaces have long reverberation times, and the Institute of Acoustics design guide says a long reverberation time lowers speech intelligibility. See classroom acoustics.

Related products: ceiling solutions, wall panels.

SEN classrooms and resource bases

For new build, BB93 sets 30 dB ambient noise and 0.4 s reverberation in a teaching space intended specifically for pupils with special hearing or communication needs (DfE, BB93, Feb 2015). See SEN classroom and resource base.

Related products: wall panels, wall tiles.

Dining halls

BB93 lists a dining room at 1.0 s reverberation for new build and 1.5 s for refurbishment (DfE, BB93, Feb 2015). DfE's inclusive estates guidance suggests sound absorbing materials and quieter dining areas (DfE, Jun 2026). See dining hall acoustics.

Related products: ceiling solutions, hanging dividers.

Sports halls

Large, hard, parallel surfaces reflect sound many times and can cause flutter echo. For new build BB93 limits reverberation by floor area, from 1.5 s under 280 m² to 2.0 s above 530 m² (DfE, BB93, Feb 2015). See sports hall acoustics.

Related products: ceiling solutions.

Corridors and shared spaces

BB93 gives corridors and stairwells no table 6 figure and points to the absorption calculation in Approved Document E, section 7 (DfE, BB93, Feb 2015). DfE names busy circulation routes among the features that can intensify overwhelm for pupils with SEND (DfE, Jun 2026).

Related products: wall panels, freestanding screens.

How a project works

  1. Survey. Joe Sutcliffe, our Managing Director and Lead Acoustic Surveyor, personally carries out the site survey, including reverberation time (RT60) assessments. A survey typically takes one to two hours on site; larger or more complex sites can take three to four hours. See acoustic survey.
  2. Recommendations. You receive a written report with recommendations within five working days.
  3. Installation. Our own in-house installation team fits the treatment. We schedule school installations outside teaching hours wherever possible, typically in the evenings, at weekends or in school holidays, and most classroom installations are complete within a single day.
  4. Post-installation testing. When the work is finished we test the room again, and Joe is closely involved in that testing. See post-installation acoustic test.

Funding

GOV.UK describes high needs provision capital allocations as a Department for Education grant paid to local authorities in England for capital projects that provide places for children and young people with SEND and improve existing provision. The guidance names enhanced acoustics as one example of how inclusive education estates can affect wellbeing and engagement, but it sets aside no money for acoustic work and leaves the choice of projects to each local authority. Whether a particular project could be funded is a question for your local authority. See SEND capital funding.

Questions schools ask

Does acoustic treatment need building work?

Absorbing treatment works on the sound inside a room, which is a different job from soundproofing; soundproofing depends mainly on the mass and construction of walls and floors (absorption versus soundproofing). Freestanding screens need no fixings, and the survey sets out what each room needs. DfE says acoustic professionals' advice should be sought where a material change to the building fabric is planned (DfE, Jun 2026).

How long does installation take?

Most classroom installations are complete within a single day; larger spaces such as halls take longer. We schedule installations outside teaching hours wherever possible.

Is BB93 a legal requirement?

No. BB93 is Department for Education guidance. The legal duties are in the Building Regulations (Requirement E4) and the School Premises Regulations 2012, and BB93 describes the normal way to meet them (DfE, BB93, Feb 2015).

Can treatment be added to an existing classroom?

Yes. BB93 gives separate refurbishment values, 0.8 s for a primary classroom and 1.0 s for a secondary classroom, and aims for the new build standard where new elements such as ceilings are installed (DfE, BB93, Feb 2015). See retrofit acoustic treatment.

Who carries out the survey?

Joe Sutcliffe, Managing Director and Lead Acoustic Surveyor, personally carries out our site surveys and reverberation time assessments. A standard survey typically takes one to two hours on site; larger or more complex sites can take three to four hours.

Talk to us about your school

Book a site survey and we will measure the rooms that matter most.

Book a site survey

Joe Sutcliffe, Managing Director of Presentation Spaces

Reviewed by Joe Sutcliffe, Managing Director & Lead Acoustic SurveyorUpdated 19 November 2026

Expert acoustic consultancy and installation for schools, businesses and restaurants across the UK. Specialists in SEN environments.
A specialist division of: Presentation Spaces Group

COMPANY

About
Why Acoustics
Contact Us
Privacy Policy
Glossary
Acoustics statistics

SECTORS

Schools
Businesses
Restaurants

SERVICES

Acoustic Surveys
Acoustic Design
Installation
© 2026 WorkSpace Acoustics Ltd. All rights reserved.
Product images courtesy of Presentation Spaces Group (used with permission)