What are the acoustic requirements for an open plan teaching space?
An open plan teaching space is a learning area without full partitions between teaching groups. BB93 sets a reverberation time of 0.5 s or less, indoor ambient noise of 40 dB LAeq,30min for new build, and speech transmission index targets of at least 0.6 within a group and no more than 0.3 between groups.[1]
Key points
- Open plan teaching areas have stricter reverberation limits than enclosed classrooms: 0.5 s, against 0.6 s for a new build primary classroom.[1]
- The speech transmission index (STI) criteria apply through the School Premises Regulations, the Independent School Standards and the Equality Act, and are not part of the normal means of satisfying Requirement E4.[1]
- BB93 says open plan spaces should not be regarded as a simple alternative to traditional classrooms, and may be unsuitable for some children.[1]
- STI modelling is essential for moderate and high risk open plan arrangements identified by the design guide's risk matrix.[1]
How it works
In an enclosed room, speech intelligibility can be secured through ambient noise, sound insulation and reverberation limits. BB93 says open plan spaces need more, because noise from activities in adjacent learning areas and circulation spaces raises the background noise level, which lowers speech intelligibility and can cause distraction.[1] Occupants raise their vocal effort as background noise rises, causing a spiralling increase that large amounts of absorption can reduce but not eliminate.[1]
The design guide says shorter reverberation times are required in open plan classrooms than in enclosed ones, because without full partitions the signal to noise ratio is reduced by intrusive noise.[2] It describes three layouts: fully open plan, semi-open plan, and flexible open plan.[2]
The numbers
BB93 gives these figures.[1]
- Open plan teaching area, indoor ambient noise: 40 dB LAeq,30min new build, 45 dB refurbishment.[1]
- Open plan teaching area, reverberation Tmf: 0.5 s or less for both new build and refurbishment.[1]
- Open plan resource or breakout area: 1.2 s or less for both new build and refurbishment.[1]
- STI for instruction or critical listening within a group: at least 0.6. Between groups during critical listening: no more than 0.3.[1]
- A higher STI value may be more appropriate for pupils with special hearing or communication needs.[1]
The design guide says the Lombard effect does not start until the background noise level exceeds 45 dBA, and recommends a target ambient level of 40 dBA to help mask speech from adjacent spaces without harming intelligibility within the classbase.[2]
In schools and SEN settings
BB93 says open plan teaching and learning spaces may be unsuitable for some children, particularly those with special hearing or communication needs, and that school client bodies should anticipate the needs of deaf and other disabled children when they consider open plan accommodation.[1] It strongly recommends independent advice from a suitably qualified acoustic technical adviser and an STI requirement in the design brief.[1] The design guide says it is unlikely that well designed open plan schools provide a significantly more cost-effective solution than enclosed classrooms.[2] The National Deaf Children's Society says hearing aids and cochlear implants make all the sounds in a room louder, not just the ones a child wants to hear, and are most effective when the speaker is under 2 metres away.[3]
Worked example
These figures are illustrative, not a measured room. An open plan teaching area of 100 m² with a 3 m ceiling has a volume of 300 m³.[2] The Sabine relation quoted in the design guide gives total absorption for 0.5 s of 0.161 × 300 ÷ 0.5 = 96.6 m².[2] That meets the reverberation criterion only. BB93 says Tmf and ambient noise act as a safeguard, while STI calculations are required to place absorption, diffusion and screening precisely for a specific activity plan.[1]
What people get wrong
- Treating 0.5 s as the whole requirement. BB93 requires STI calculations, for new build and refurbishment alike, for open plan spaces to comply with the School Premises Regulations.[1]
- Assuming open plan is a cheaper classroom. BB93 says it is not a simple alternative, and the design guide doubts the saving.[1][2]
- Using STI 0.6 as a universal target. BB93 says a higher value may suit pupils with special hearing or communication needs.[1]
How it is checked
BB93 says STI should be calculated in accordance with EN 60268-16, using a computer prediction model of the space with a documented activity management plan.[1] The model should use the overall occupancy noise level as background noise.[1]
FAQ
What is the BB93 reverberation time for an open plan teaching area?
It is 0.5 s or less for new build and refurbishment alike.[1]
What STI does BB93 require?
At least 0.6 for instruction within a group and no more than 0.3 between groups during critical listening.[1]
Is STI part of Building Regulations Part E?
No. BB93 says STI criteria are not in the normal means of satisfying Requirement E4, but are needed for the School Premises Regulations.[1]
WorkSpace Acoustics surveys and installs acoustic treatment for schools; contact the team to discuss a room.
Sources
- Acoustic design of schools: performance standards (Building Bulletin 93). Department for Education, February 2015. Accessed November 2026.
- Acoustics of Schools: a design guide. Institute of Acoustics and Association of Noise Consultants, November 2015. Accessed November 2026.
- Creating good listening conditions. National Deaf Children's Society, last reviewed May 2025. Accessed November 2026.